2-49
Cisco Catalyst Switch Module 3110 and 3012 for IBM BladeCenter System Message Guide
OL-12191-01
Chapter 2 Message and Recovery Procedures
PLATFORM_ENV Messages
PLATFORM_ENV Messages
This section contains platform-specific environment messages.
Error Message
PLATFORM_ENV-1-FAN: Faulty fan detected.
Explanation
A faulty fan is detected.
Recommended Action
If the message appears again, immediately replace the switch fan.
Error Message
PLATFORM_ENV-1-FAN_NOT_PRESENT: Fan is not present.
Explanation
The fan is not in the switch.
Recommended Action
If the fan is removable, remove and replace it into the switch. If the problem
persists after insertion, replace the fan.
Error Message
PLATFORM_ENV-1-FRU_PS_ACCESS: [chars].
Explanation
The switch failed to access the power supply due to a communication problem. [chars]
is the error message.
Recommended Action
This problem could be transient. If the problem persists, replace the power
supply.
Error Message
PLATFORM_ENV-1-TEMP: Abnormal temperature detected.
Explanation
An abnormal temperature is detected.
Recommended Action
Ensure that ambient temperature is not too high. If the problem persists, check
the switch temperature by entering the
show env all
privileged EXEC command.
PLATFORM_FBM Messages
This section contains the platform fallback bridging manager (FBM) messages.
Error Message
PLATFORM_FBM-4-RECOVERED: Fallback bridging recovered from resource
crunch.
Explanation
Fallback bridging has recovered from an earlier lack of resource.
Recommended Action
No action is required.