2-60
Cisco Catalyst Switch Module 3110 and 3012 for IBM BladeCenter System Message Guide
OL-12191-01
Chapter 2 Message and Recovery Procedures
PLATFORM_UCAST Messages
Error Message
PLATFORM_UCAST-3-HSRP: [chars].
Explanation
The Hot Standby Router Protocol (HSRP) module for unicast routing encountered an
error. [chars] describes the error.
Recommended Action
Copy the message exactly as it appears on the console or in the system log.
Research and attempt to resolve the error by using the Output Interpreter. Use the Bug Toolkit to
look for similar reported problems. If you still require assistance, contact IBM technical support and
provide the representative with the gathered information. For more information about the online
tools and about contacting IBM, see the
“Error Message Traceback Reports” section on page 1-6
Error Message
PLATFORM_UCAST-3-INTERFACE: [chars].
Explanation
A unicast routing interface error occurred. [chars] describes the error.
Recommended Action
Copy the message exactly as it appears on the console or in the system log.
Research and attempt to resolve the error by using the Output Interpreter. Use the Bug Toolkit to
look for similar reported problems. If you still require assistance, contact IBM technical support and
provide the representative with the gathered information. For more information about the online
tools and about contacting IBM, see the
“Error Message Traceback Reports” section on page 1-6
Error Message
PLATFORM_UCAST-3-RPC: [chars].
Explanation
The RPC module for unicast routing encountered an error. [chars] describes the error.
Recommended Action
Copy the message exactly as it appears on the console or in the system log.
Research and attempt to resolve the error by using the Output Interpreter. Use the Bug Toolkit to
look for similar reported problems. If you still require assistance, contact IBM technical support and
provide the representative with the gathered information. For more information about the online
tools and about contacting IBM, see the
“Error Message Traceback Reports” section on page 1-6
Error Message
PLATFORM_UCAST-6-PREFIX: One or more, more specific prefixes could not
be programmed into TCAM and are being covered by a less specific prefix
Explanation
The more specific prefix could not be programmed into Ternary Content Addressable
Memory (TCAM) and is covered by a less specific prefix. This could be a temporary condition. The
output of the
show platform ip unicast failed route
privileged EXEC command lists the failed
prefixes.
Recommended Action
No action required.