background image

VCC-5CL1M  

Rev. 

905-0003-02 

 

   

©2015 CIS Corporation. All rights reserved. 

33 

 

 

14.3.

 

Precaution and Instruction

 

 

 

When changing the sequence settings (address 72-82), make sure that sequence control (address 70) is set to OFF.    Re-set the sequence control to Auto Mode or 
CC Mode after sequence setting again. 

 

Sequence control (address 70) cannot be SAVE or INIT, set manually after the power is turned on. (The other sequence settings can be SAVE or INIT.) 

 

It is selectable from 2560, 2048, 1920 pixel at horizontal size in sequence control, however, as for the time of 1 line the blanking period will change with the 
maximum of the horizontal pixels set in address 55 beforehand.     

 

Make more than 80

μ

s exposure time in sequence mode. 

 

Minimum trigger interval is 80

μ

s + 25lines (V Blanking width). 

 
 

The most fast Operation Cycle of each Mode in Sequence Control 

 

2Tap Mode 

4Tap Mode 

8Tap Mode 

10Tap Mode 

Horizontal 2560 

Pixels

 

Effective Line (Exposure Line Count)

10 

20 

24 

Unit: line 

Total Line Count 

31 

35 

45 

49 

Unit: line 

Cycle 

499.88  

284.38  

185.63  

168.44  

Unit: µs 

Frame Rate 

2001  

3516  

5387  

5937  

Unit: fps 

Horizontal 2048 

Pixels

 

Effective Line (Exposure Line Count)

14 

26 

30 

Unit: line 

Total Line Count 

33 

39 

51 

55 

Unit: line 

Cycle 

429.00  

253.50  

165.75  

151.25  

Unit: µs 

Frame Rate 

2331  

3945  

6033  

6612  

Unit: fps 

Horizontal 1920 

Pixels

 

Effective Line (Exposure Line Count)

14 

26 

32 

Unit: line 

Total Line Count 

33 

39 

51 

57 

Unit: line 

Cycle 

400.13  

238.88  

157.23  

147.23  

Unit: µs 

Frame Rate 

2499  

4186  

6360  

6792  

Unit: fps 

 
 
 
 

Содержание VCC-5CL1M

Страница 1: ...VCC 5CL1M Rev 905 0003 02 2015 CIS Corporation All rights reserved Camera Link I F 5 2M Pixels CMOS B W Camera VCC 5CL1M Product Specifications Operational Manual CIS Corporation English...

Страница 2: ...Base Configuration Mode 30fps 17 7 3 Horizontal Synchronous Signals Timing 4Tap Medium Configuration Mode 59fps factory settings 18 7 4 Vertical Synchronous Signals Timing 4Tap Medium Configuration M...

Страница 3: ...5CL1M Rev 905 0003 02 2015 CIS Corporation All rights reserved 2 18 Dimensions 37 19 Cases for Indemnity Limited Warranty 38 20 CMOS Pixel Defect 38 21 Product Support 38 22 Ordering Information TBD...

Страница 4: ...cold places operating temperature 5 to 4 5 Close to generators of powerful electromagnetic radiation such as radio or TV transmitters Places subject to fluorescent light reflections Places subject to...

Страница 5: ...r is utilized Camera Link Base Configuration Medium Configuration Full Configuration and 8Tap 10Tap Deca Configurations are supported Fixed trigger shutter mode and pulse width trigger shutter mode ar...

Страница 6: ...onfiguration 8Tap 10bit Configuration 5 Resolution 2048 TV Lines 6 Output Format Sensor ADC 12bit Camera Link output 8bit 10bit 12bit 8bit 10bit at 8Tap mode 8bit at 10Tap mode B W output 7 Sensitivit...

Страница 7: ...amera functions operate normally under operation guaranteed temperature Humidity RH 20 80 with no condensation 24 Storage Environment Temperature 25 60 Humidity RH 20 80 with no condensation 4 2 Camer...

Страница 8: ...DR mode setting Address 90 Up to 6 seconds shall be required after turning on power to get proper camera operation 4 3 Input output Circuitry of 12pin circular connector 12pins connector Pin No 11 Tri...

Страница 9: ...ue to a pull up voltage a pull up resistor and a connecting circuit of user s circuit Need to set up a value to become an appropriate waveform exp_out of 12pins connector Pin No 9 is a pulse without d...

Страница 10: ...esponse the lens characteristic and the illuminant characteristic are excluded 4 5 Video Output Format 1 2Tap Base Configuration Mode 30fps Full Frame 2 4Tap Medium Configuration Mode 59fps Full Frame...

Страница 11: ...rporation All rights reserved 10 3 8Tap Configuration Mode 117fps Full Frame 4 10Tap Configuration Mode 140fps Full Frame D D D D D D D D 2048 Line 2560 Pixel 1 2 3 4 5 6 7 8 D D D D D D D D D D 2048...

Страница 12: ...OSURE 1 7pin FVAL isolated FVAL 9pin TTL EXPOSURE 2 7pin isolated EXPOSURE 9pin TTL FVAL 3 7pin FVAL isolated FVAL 9pin TTL FVAL Cursor Display ON OFF 8 0 OFF 1 ON Cursor X Address 9 0 2559 0 2560 Hor...

Страница 13: ...orizontal 1920 Pixels Binning 56 0 OFF 1 2x2 Binning 2 4x4 Binning Sequence Control 70 0 OFF 1 Auto mode 2 CC mode Sequence Index Number 72 0 7 The number of active indexes Sequence Index 73 8 Params...

Страница 14: ...000 1 10000 12 1 14000 1 16000 1 16000 1 15000 13 1 26000 1 26000 1 25000 1 24000 14 1 44000 1 44000 1 53000 1 49000 15 1 44000 1 68000 1 93000 1 99000 2048 Pixel x 2048 Line Set Data 2tap Mode 4tap M...

Страница 15: ...32000 1 32000 1 31000 14 1 53000 1 53000 1 63000 1 59000 15 1 53000 1 78000 1 103000 1 108000 5 2 Calculation of Exposure Time by Shutter The exposure time by manual shutter is calculated with 1H widt...

Страница 16: ...ment 6 1 12 pins Circular Connector HR10 10R 12PA HIROSE equivalent Pin No Signal 1 GND 2 Power Input DC 11V 24 5V 3 NC 4 NC 5 GND 6 TRIGGER Input isolated 7 EXPOSURE FVAL Output isolated 8 GND 9 EXPO...

Страница 17: ...ighting At power feeding from PoCL Blinking At power feeding either only from CL1 cable or only from CL2 cable Lighting At power feeding from both CL1 cable and CL2 cable The required current exceeds...

Страница 18: ...CLK 80MHz Camera Link Port A 1 3 5 7 2 4 6 8 2553 2555 2557 2559 2554 2556 2558 2560 1 2 Video Out 25 59 25 60 7 2 Vertical Synchronous Signals Timing 2Tap Base Configuration Mode 30fps When a read o...

Страница 19: ...amera Link CLK 80MHz Camera Link Port A 1 3 5 7 2 4 6 8 2553 2555 2557 2559 2554 2556 2558 2560 1 2 Video Out 25 59 25 60 3 4 25 57 25 58 7 4 Vertical Synchronous Signals Timing 4Tap Medium Configurat...

Страница 20: ...Mode 117fps When a read out period FVAL 1 and an exposure start up start up of Exposure Time overlap LVAL and DVAL output Lo for 4H and also stop the image output In this case Lo period V Blanking wid...

Страница 21: ...ps 7 8 Vertical Synchronous Signals Timing 10Tap Configuration Mode 140fps When a read out period FVAL 1 and an exposure start up start up of Exposure Time overlap LVAL outputs Lo for 4H and also stop...

Страница 22: ...12 6 11 1 Horizontal 1920 pixel 39 4 21 2 12 1 10 6 unit s The exposure period of Exposure output TTL is approx 1 s at leading edge and is approx 8 s at trailing edge The min setting value of Fixed Tr...

Страница 23: ...re Time Delay 2Tap 4Tap 8Tap 10Tap Horizontal 2560 Pixel 49 0 24 8 12 8 10 8 Horizontal 2048 Pixel 39 7 20 0 10 2 8 6 Horizontal 1920 Pixel 37 0 18 9 9 7 8 2 unit s The actual exposure period becomes...

Страница 24: ...ffective Line Trigger input ignore period Exposure Time Delay Exposure Time Delay A TRIG IN SP Out Exposure Out Exposure time delay Exposure Time Effective Line 8 Binarization Camera output level can...

Страница 25: ...address 42 to 512d Barcode Based on the brightness distribution of edge areas in image the threshold value is calculated automatically inside the camera The object which has a lot of edges such as bar...

Страница 26: ...correction is performed by setting ON a shading correction address 43 9 1 Shading Detection When the object with uniform levels such as a pattern box is imaged on the whole screen and a shading detect...

Страница 27: ...ps 2048 Max 2048 2073 29 9 fps 59 4 fps 116 9 fps 140 3 fps Setting Examples in case of Horizontal 2048 1920 pixels Horizontal x Vertical Effective Lines Entire frame lines Frame Rate Entire frame lin...

Страница 28: ...nd 1920pixels Center position is fixed at Horizontal Partial This mode is applicable along with Vertical Partial Just at 10tap 2048 pixels change to 2050 pixels The last 2 pixels are dummy 2048 Line 2...

Страница 29: ...es are set to one half 1 2 frame rate rises and exposure time is also set to one half 1 2 Not applicable in conjunction with Horizontal and Vertical Partial 4x4 binning Four by four pixels are mixed a...

Страница 30: ...set a Command Input a command in capital letters Separate between a command and a parameter by one space From the head of input character to the linefeed code r or n is analyzed as one command Input...

Страница 31: ...ain Setting ROI start position X Y Horizontal Size Vertical Size Operation sequence is specified as Index The parameter set number to be applied is specified against 8 Index es at maximum For control...

Страница 32: ...ch Index and the Index number to be used can be set up Index changes whenever a trigger is input and the parameter values are applied to the camera Auto Mode Flow Chart Sequence Index repeats address...

Страница 33: ...h CC2 CC3 and CC4 signal Index specified by CC signal is selected whenever a trigger is input and corresponding parameter values are applied to the camera CC Mode Flow Chart Sequence Index address 73...

Страница 34: ...dress 55 beforehand Make more than 80 s exposure time in sequence mode Minimum trigger interval is 80 s 25lines V Blanking width The most fast Operation Cycle of each Mode in Sequence Control 2Tap Mod...

Страница 35: ...Binning Mode OFF Others are prohibited The increment of the dynamic range can be selected among 4 modes by HDR Mode Settings Address 90 The above table shows reference values at 2048 lines of Exposure...

Страница 36: ...Circular Connector Output 7 0 7pin Exposure isolate 9pin Exposure TTL Cursor Display 8 0 OFF Horizontal Flip 11 0 OFF Defective Pixel Correction 13 1 ON Defective pixels at ex factory are corrected Ga...

Страница 37: ...VCC 5CL1M Rev 905 0003 02 2015 CIS Corporation All rights reserved 36 17 CMOS Optical Axis Accuracy...

Страница 38: ...VCC 5CL1M Rev 905 0003 02 2015 CIS Corporation All rights reserved 37 18 Dimensions...

Страница 39: ...this product specification operation manual z In case damage or losses are caused by malfunction or other problems resulting from use of equipment or software that is not specified z In case damage or...

Отзывы: