VCC-5CL1M
Rev.
905-0003-02
©2015 CIS Corporation. All rights reserved.
21
7.9.
Fixed Trigger Shutter Mode
□
This is the mode to start exposure with external input trigger signals, and set the exposure time with
serial communication command.
□
Trigger operation is Clock-sync and H/V-sync Restart system.
□
The delay time (Exposure Time Delay) from detecting trigger edge in the camera to Exposure output
(TTL) differs in each mode mentioned below.
Exposure Time Delay
2Tap
4Tap
8Tap
10Tap
Horizontal 2560 pixel 51.4
27.2
15.1
13.1
Horizontal 2048 pixel 42.0
22.4
12.6
11.1
Horizontal 1920 pixel 39.4
21.2
12.1
10.6
unit
:
µs
□
The exposure period of Exposure output
(
TTL
)
is approx. 1
µ
s
at leading edge and is approx. 8
µ
s
at trailing edge.
□
The min. setting value of Fixed Trigger Shutter Mode is 1H( min.).
(
Depends on each Tap mode and horizontal pixels
)
□
The next trigger can be accepted during outputting a current image. However, while the image output is not
completed, do not input the trigger signal of the image exposure settings to start the next output.
□
The camera ignores any trigger input between Exposure Time start and Read-out start. Refer to (A) in the drawing
below. When a read-out period (FVAL=1) and an exposure start-up (start-up of Exposure Time) overlap, LVAL and
DVAL output Lo for 4H, and also stop an image output.