7.3.
Horizontal Synchronous Signals Timing (4Tap Medium Configuration Mode: 59fps)
*factory settings
Camera Link Port D
Camera Link Port C
LVAL Out
~ ~
Effective Data : 640 CLK
10 CLK
DVAL Out
1H = 650 CLK
~ ~
Camera Link Port B
・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・
Camera Link CLK : 80MHz
Camera Link Port A
1
3
・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・
5
7
2
4
6
8
2553
2555
2557
2559
2554
2556
2558
2560
1
2
Video Out
25
59
25
60
3
4
~ ~
25
57
25
58
7.4.
Vertical Synchronous Signals Timing (4Tap Medium Configuration Mode: 59fps)
□
When a read-out period (FVAL=1) and an exposure start-up (start-up of Exposure Time) overlap, LVAL and DVAL output
Lo for 4H, and also stop the image output. In this case, Lo period (V Blanking width) of FVAL shortens by 4H.
□
At the start-up of FVAL, LVAL outputs Lo for approx.1H.