14.2.
CC mode
The mode to specify the Index number to be applied directly with CC2, CC3, and CC4 signal
Index specified by CC signal is selected whenever a trigger is input, and corresponding parameter values are applied to the camera.
CC Mode Flow Chart
Sequence Index
(address 73)
Connection of each Index and
the Parameter sets
Input Output
CC4
CC3
CC2
Index No.
L L L
0
L L H
1
L H L
2
L H H
3
H L L
4
H L H
5
H H L
6
H H H
7