3�3�- STORAGE FOR LONG PERIODS
If the device is not installed after receipt, the following recommendations must be observed to keep
the device in a good state:
Keep the device in a dry atmosphere and at a temperature of between -20ºC and 50ºC.
Avoid exposure to direct sunlight.
Keep the device in its original packaging.
If the static generator is stored for a long time disconnected from the mains, a specific process must
be applied to restore the internal dielectric layers of the DC bus capacitors.
shows the recom-
mendations for starting the device, according to the length of its storage period.
Table 13: Start-up process, according to storage time�
Storage time
Process
< 1 year
No special treatment required.
> 1 year
Connect the
SVGm
to the mains at least one hour before
starting up the device. Power the device and leave it in STOP
mode
3�4�- INSTALLATION
3�4�1�- WALL-TYPE SVGm
The Wall-type
SVGm
has a number of holes on the top and bottom of the device,
to facilitate
transport and installation of the device.
These holes can be used as attachment points for external manipulation tools, or a bar (not included)
can be passed through them to improve transport and installation of the device.
Figure 4: Holes to facilitate transport and installation�
The device must be fixed vertically to a wall or support.
Use 4 fixing screws with a diameter of
8 mm
, suitable for the chosen wall or support.