4.7.- RESIDUAL CURRENT
(eHome TxC32-A, - B, -A MID models)
Note:
Residual current is only available on models:
eHome T1C32-A, T1C32-B, T1C32-A MID,
T2C32-A, T2C32-B
y
T2C32-A MID
.
4�7�1�- RESET THE RESIDUAL CURRENT DEVICE
The Residual-Current Device (RCD) installed in the different
eHome
models must be reset in
case of actuation.
To reset the Residual-Current Device (RCD), previously, it is needed to check the possible
electrical risk for the user.
1�-
Beware the
eHome
is disconnected to the power line. And similarly, the unit must be discon-
nected by the Miniature Circuit Breaker (MCB) of the power line.
2�-
Beware the Vehicle is not connected to the device.
3�-
Check the status of the cable and the plug of the device.
4�-
Check the plug, not being in contact with wet surface of directly with water.
5�-
After checking the possible damages of the cable and the plug of the device with its possible
contact with water. It is necessary to check that the cable and the plug have no suffered any
damage of overcurrent.
During the RCD reset operations, it must be checked the properly status of the
cable and plug, not being dirty or damaged, and likewise, not having wet sur-
faces close to the device.
6�-
After the properly checked of the previous points, it is possible to make the reset in the RCD
Figure 37: RCD type A and RCD type B
Note:
Once it has been made the properly checked of the points exposed before, and it is
not possible to reset the RCD. It will be necessary to disconnect the unit and call for a correct
trained, qualified and authorized technician.