80
15.5 - TANK LEVEL GAUGE CLEANING
1. With a suitable pliers release the clamp (1 and
2) fixing transparent tube of the level gauge.
2. Take off and remove the transparent tube (3).
3. Remove the red plastic ball (4) .
4. Clean, whit clean water, the trasparent tube
both in and ouside.
Gather the rinsing water in a proper
container provided to be waste
according to the rules or used again,
putting it in the tank, for a next
treatment if suitable with the
product to be used.
5. If the cleaning is not satisfactory, replace the
transparent tube (3).
Waste the transparent tube
according to the same method as
per the pesticides container.
6. Put the red plastic ball (4) into the transparent
tube (3).
7. Install the transparent tube (3) making slip it
on the rubber fittings.
8. Place the clamps (1 and 2) fixing the transpa-
rent tube (3) of the level gauge and close them
with a suitable pliers.