SERVICE MANUAL
Transmig 165
ST
Transmig 165
ST
SERVICE MANUAL
Transmig 165
ST
Transmig 165
ST
TROUBLESHOOTING 10-8 Manual 0-5442
10.11 DC Bus voltage measurement
Apply voltage to the Power Source.
There are extremely dangerous voltage and power levels present inside these Power
Sources. Do not attempt to diagnose or repair unless you have had training in power electronics measure-
ment and troubleshooting techniques.
Once power is applied to the Power Source, there are extremely hazardous voltage and power levels pres-
ent.
Do not touch any live parts.
4
3
1
2
5
6
7
8
10
9
12
11
14
13
16
15
17
18
19
20
21
22
A-09988
DC Bus Testing
Multimeter Lead Placement
Voltage with Supply voltage OFF
Upper capacitor bank
Positive meter lead to testpoint 1
Negative meter lead to testpoint 2
168 VDC +/-10%
Lower capacitor bank
Positive meter lead to testpoint 3
Negative meter lead to testpoint 4
168 VDC +/-10%
Overall capacitor bank
Positive meter lead to testpoint 1
Negative meter lead to testpoint 4
336 VDC +/-10%
Table 10-10 DC BUS, Multimeter set to measure DC volts
Note: These DC voltages are at nominal mains supply voltage of 240VAC.
Содержание Transmig 165ST
Страница 16: ...SERVICE MANUAL Transmig 165ST Transmig 165ST GENERAL INFORMATION 1 10 Manual 0 5442 Notes ...
Страница 32: ...OPERATION 4 6 Manual 0 5442 SERVICE MANUAL Transmig 165ST Transmig 165ST Notes ...
Страница 84: ...SERVICE MANUAL Transmig 165ST Transmig 165ST THEORY OF OPERATION 9 2 Manual 0 5442 Notes ...
Страница 115: ...SERVICE MANUAL Transmig 165ST Transmig 165ST Manual 0 5442 12 3 ASSEMBLY PROCEDURE 8 7 A 10011 9 A 10012 ...
Страница 118: ...SERVICE MANUAL Transmig 165ST Transmig 165ST ASSEMBLY PROCEDURE 12 6 Manual 0 5442 14 Art A 13011 ...
Страница 120: ...SERVICE MANUAL Transmig 165ST Transmig 165ST ASSEMBLY PROCEDURE 12 8 Manual 0 5442 Notes ...
Страница 125: ...SERVICE MANUAL Transmig 165ST Transmig 165ST This Page Intentionally Blank ...