19
No.
Description
Setting
Default
Display conditions
I
NPUTS
(
CONTINUED
)
1
418 Check of manual HP1 pressure switch input Open/Closed
1
419 Check of stage 1, circuit 1 fault input
Open/Closed
1
420 Check of stage 2, circuit 1 fault input
Open/Closed
If P4 = 2
1
422 Check of manual HP2 pressure switch input Open/Closed
If P3 = 2
1
423 Check of stage 1, circuit 2 fault input
Open/Closed
If P3 = 2
1
424 Check of stage 2, circuit 2 fault input
Open/Closed
If P5 = 2
1
425
Check of fault input for circuit 1 electronic
expansion valve
Open/Closed
If P42 = ALCO
1
426 Check of fault input for circuit 2 electronic
expansion valve
Open/Closed
If P42 = ALCO
O
UTPUTS
1
430 Pump 1 control state
On/Off
1
431 Pump 2 control state
On/Off
If (P2 = 1) or P25 = 2
1
432 State of circuit 1 Y/C control output
On/Off
If P2 = 3
1
433 State of circuit 2 Y/C control output
On/Off
If P2 = 3 and P3 = 2
1
435 State of heat trace cable control output
On/Off
If P2 ≠ 1 (water-to-water)
1
436 State of heater control output
On/Off
If P2 ≠ 1 (water-to-water)
1
437 State of recovery heat trace cable control output On/Off
If P2 ≠ 1 (water-to-water) and P29.1 = Yes
1
438 State of maximum power output
On/Off
If P111 = Max. power
1
439 State of boiler output
On/Off
If P111 = Boiler
1
440 State of cooling/heating output
On/Off
If P111 = Cooling/Heating
1
441 State of HP control output, stage 1, circuit 1
On/Off if P21 = without
High Temperature mode/Low Noise mode/Off if
P191 = acoustic
If P21 = without, P2 = 2, 3
1
442 State of HP control output, stage 2, circuit 1 On/Off
If P180 = 2 and P3 = 1, P2 = 2, 3
1
443 State of HP control output, stage 1, circuit 2 On/Off
If P180 = 1 and P3 = 2, P2 = 2, 3
1
444 State of HP control output, stage 2, circuit 2 On/Off
If P180 = 2 and P3 = 2, P2 = 2, 3
1
445
State of HP control output, stage 3, circuit 1
or
State of HP control output, common stage 1
On/Off
If P180 = 3 and P3 = 2
P11 = split P2 = 2, 3 or If P180 = 3 and
P3 = 2 P11 = mixed
1
446
State of HP control output, stage 3, circuit 2
or
State of HP control output, common stage 3
On/Off
If P180 = 3 and P3 = 2
P11 = split P2 = 2, 3 or If P180 = 3 and
P3 = 2, P11 = mixed
1
447 Driving voltage, stage 1, HP control
0-10 V
If P21 = 2 or 3 and P11 = Intertwined
1
448 Driving voltage, stage 1, circuit 1, HP control 0-10 V
If P21 = 2 or 3 and P11 = split or mixed
1
449 Driving voltage, stage 1, circuit 2, HP control 0-10 V
If P21 = 2 or 3 and P11 = split or mixed
1
450 Driving voltage, common stage 1, HP control 0-10 V
If P21 = 2 or 3 and P11 = Mixed
1
451 State of circuit 1 balance valve output
On/Off
If P12 = Yes
1
452 State of circuit 2 balance valve output
On/Off
If P12 = Yes
1
530 State of electric stage 1
On/Off
If P22 = Yes
1
531 State of electric stage 2
On/Off
If P22 = Yes
1
532 State of electric stage 3
On/Off
If P22 = Yes
1
533 State of electric stage 4
On/Off
If P22 = Yes and P112 = 4
1
535 Air blade percentage information
0-100%
If P20 =Yes and P10 = Centrifugal
1
555 CPU version number
1
556 Console version number
*
1
557 Version number of circuit 2 board
If P3 = 2
1
558 Version number of changeover board
If P2 = reversible air-to-water
1
559 Version number of auxiliary heater board
If P22 = Yes
1
560 Version number of circuit 1 expansion valve XX.YY
VCM
XX.YY
If P42 = CIAT and P3 = 1
1
561 Version number of circuit 2 expansion valve XX.YY
VCM
XX.YY
If P42 = CIAT and P3 = 2
1
570 "SO" order number"
To be entered via a PC
1
571 MO number
To be entered via a PC
1
572 Machine identification name
To be entered via a PC
1
573 Machine identification number
To be entered via a PC