7.1 MAX/MIN : (This function only applies to the channel shown in main display) 

Pressing “MAX/MIN” button, the indicator “REC” appears at right side of LCD, the meter 

will start to record the Maximum and Minimum values and calculate average value of measure-
ment reading. 
Press “MAX/MIN” button again each time, main display changes from current measurement 
reading to maximum value recorded with indicator “MAX” below “REC”, minimum value rec-
orded with indicator “MIN” at lower right side of “REC”, the difference between maximum and 
minimum values with indicator “MAX-MIN” below “REC”, the average value during recording 
with indicator “AVG” right to “REC”, and then back to current measurement reading.   
Press and hold the “MAX/MIN” button for longer than 5 seconds to end the MAX/MIN record-
ing. 

7.2 HOLD : (This function only applies to the channel shown in main display) 

Press the “HOLD” button, the display holds the current reading and the meter stops further 

measurement. Indicator “HOLD” is shown at top of the LCD. 
Press the “HOLD” button again to release from the holding function and resume normal meas-
urement. 

 

7.3 Hi/Lo : (This function only applies to the channel shown in main display) 

Press the “Hi/Lo” button, to activate the out of limit alarm function. The indicator “LIMIT” ap-
pears at right side of LCD. 
When the measurement value is higher than upper limit the beep send out an intermittent sound.   
When the measurement value is lower than lower limit the beep send out a continuous sound.   
Press the “Hi/Lo” button again, to disable the alarm function. 
Refer to 8.15 for setting upper and lower limits. 

 
7.4 REL 

Δ

 : (This function only applies to the channel shown in main display) 

REL 

Δ

: (This function only applies to the channel shown in main display) 

Press “REL 

Δ

” to store the current value as the reference, relative value against this reference 

will be displayed for the measurements afterward.   

 

7.5 

  :

 

Press this button to turn on the backlight function, press it again to turn the backlight off. 

 
7.6 LOG (Data Logging) : 

During measuring, press “LOG” button to continuously record the measurement readings of 

the set channels at the set time interval until the “LOG” button is pressed again. 
To set the channel for LOG function, please refer to section 8.12 
To set the time interval for LOG function, please refer to section 8.18 
To read the logged data, please refer to section 8.12 

8.11 CHB RANGE-Select the Resolution for Cannel B (CHB)   

Channel B can accept the voltage signal up to 2 volts; above 2 volts display shows OL. Place 

the rotary switch at position “CHB RANGE”, change among Auto (“--.-.-” and “AUT” is shown 
in display), “0.1” (“---.-” and “MAN” is shown in display) and “0.01” (“--.—” and “MAN” is 
shown in display). 

When “Auto” is selected, the meter will select most suitable resolution between “0.1” and 

“0.01”, while the other two, the reading will be fixed in the selected resolution. 

 

8.12 MEM VIEW CLR - Selecting the channel for data logging, Read recorded data and 

Clear memory 

There are 3 functions in this position “MEM VIEW CLR” : 
 1. SET function: Select the channels for data logging. 
2. VIEW function: To read recorded data. 
3. Memory Clear function: Clear memory and erase all the recorded data. 

Place rotary switch at position “MEM VIEW CLR”, the meter enter the “Memory Access 

Functions Selection Mode” with LCD shows the indicator “MEM” at lower-right corner and a 
blinking indicator “SET” at upper-right corner. 

 
Press direction keys 

 or    to change the blinking indicator among “SET” (SET func-

tion), “VIE” (VIEW function) and “CLR” (Memory Clear function). 

To exit this function, just turn the Rotary Switch to another position. 
CLR (Memory Clear function: Clear memory and erase all the recorded data) 
 
When the blinking indicator shows “CLR”, press “

” key to enter Clear function. The blink-

ing indicator changes to “YES”. 

 
Press “

” key to clear memory and erases all the data recorded in the memory (this will take 

some seconds), and return to “Memory Access Functions Selection mode” with blinking indica-
tor “SET” at upper-right corner.   
Or press “ESC” key to abort the job and keep the data in the memory unchanged, and return to 
“Memory Access Functions Selection mode” with blinking indicator “SET” at upper-right corner. 

 
Press direction keys 

 or    to change the blinking indicator to “SET” (SET function) or 

“VIE” (VIEW function), or to exit this function by turning the Rotary Switch to another position. 

 
VIE (VIEW function : to read recorded data) 
 
There are 3 sets of data you can choose to read, namely “SAVE”, “LOG” and “LIMIT”, (cor-

responding to the functions of buttons “SAVE”, “LOG” or “ALMLOG”, respectively. Please re-
fer to section 7.6, 7.7, 7.8 for the functions of these buttons.) 

 
When the blinking indicator shows “VIE”, press “

” key to enter VIEW function. The 

blinking indicator “VIE” disappears. Indicators “READ MEM” and “SAVE” are shown at low-
er-right corner of LCD. 

13 

Содержание 506A

Страница 1: ...OPERATOR S MANUAL MODEL 506A...

Страница 2: ...r ID 001 Ex PC send 001L00006 r then meter response 001L0000111554170704111220420900115000001 r PC sends 001D00006 r then meter will dump all of data of group 6th 001D00006 rxxxxxx rxxxxxx rxxxxxx r M...

Страница 3: ...of Buttons 9 8 1 D1 Setting the Main Display 9 8 2 D2 Setting Second Display 10 8 3 D3 Setting Third Display 10 8 4 T1 TYPE and T2 TYPE Setting the Types of Thermocouple for T1 or T2 10 8 5 T1 ADJ an...

Страница 4: ...s 5 Alarm Counter AC 5 S Counts 5 Saved Data SD mode 1 mode 2 34 S GroupID SC c f mode T1_type T2_type Time Value r 5 5 1 1 1 1 12 6 2 Saved Data SD mode 3 34 S GroupID SC c f dp cha_type Time Value r...

Страница 5: ...trument contains no operator serviceable part Service should be done by qualified person only Do not use the meter if the meter or test leads look damaged or if you suspect that the meter is not opera...

Страница 6: ...S TYPE Resolution 1 0 C to 1767 C 32 F to 3212 F N TYPE Resolution 0 1 50 C to 1300 C 58 F to 2372 F Resolution 0 1 C 1 C 0 1 F 1 F Auto Ranging 2 2 Accuracy K J T E TYPE 0 05 rdg 0 3 C on 50 C to 13...

Страница 7: ...the indica tor SET shows at left side of LCD when place the rotary switch at any of these system setting positions And 2nd functions of buttons are active Y Interval year 20 00 20 99 M Interval month...

Страница 8: ...function APO Function will be Disabled also in Follow situation External power is used RS 232 function is used MAX MIN MAX MIN AVG function is used Data logger function is used 8 18 INVT Set Time inte...

Страница 9: ...e blinking position with and key Press ESC key to end the set up mode indicator C or F ends blinking and indicator SET disappears but keep the previous setting unchanged Press CANCEL key to return to...

Страница 10: ...ory Clear function or to leave this function by turning the Rotary Switch to an other position SET SET function Select the channels for data logging When the blinking indicator shows SET press key to...

Страница 11: ...on marked with turning the rotary switch to any other position automatically turns on Model 506A5 Num bers and marks appear in the LCD display When APO Auto Power Off is enabled refer to 8 17 for enab...

Страница 12: ...refer to section 8 18 To read the logged data please refer to section 8 12 8 8 11 CHB RANGE Select the Resolution for Cannel B CHB Channel B can accept the voltage signal up to 2 volts above 2 volts...

Страница 13: ...And not function when LOG function is set as multi channel logging During measuring press SAVE button to record current measurement reading of the channel shown in Main Display and time To read the r...

Страница 14: ...are known the offset adjustments can be set to each of T1 and T2 for compensating the off set er ror 10 RTD TYPE 8 6 CHA TYPE Selecting the Types of RTD for CHA Besides accepting the RTD of type Pt 38...

Отзывы: