Command
Description
Values
option cards that have loop out. (Saved
value)
LOP–Lamp Selection
Selects a lamp to turn on or off while in limited power mode.
If LOP or LOP+MULT try to enable any lamps that are not installed, the command fails.
Commands
Command
Description
Values
LOP <lamp>
Selects a lamp to turn on or off while in limited power
mode. This command is disabled while in the Power On
state. (Saved value)
1 = Lamp A1 (Default)
2 = Lamp A2
3 = Lamp A3
4 = Lamp B1
5 = Lamp B2
6 = Lamp B3
LOP+MULT <value>
Selects which lamps are meant to be active. At least
one lamp must be active. This command is only
available in full power mode. (Saved value)
Valid bitmapped fields:
• bit0 = Lamp A1
• bit1 = Lamp A2
• bit2 = Lamp A3
• bit3 = Lamp B1
• bit4 = Lamp B2
• bit5 = Lamp B3
value = A bitmapped field
ranging from 1 to 63
63 = All lamps are active
(Default)
LOP+MULT valid values
The model of projector determines the number of lamps in the projector.
Value
Lamp A1
(bit0)
Lamp A2
(bit1)
Lamp A3
(bit2)
Lamp B1
(bit3)
Lamp B2
(bit4)
Lamp B3
(bit5)
1
On
Off
Off
Off
Off
Off
2
Off
On
Off
Off
Off
Off
3
On
On
Off
Off
Off
Off
4
Off
Off
On
Off
Off
Off
5
On
Off
On
Off
Off
Off
6
Off
On
On
Off
Off
Off