Command
Description
Values
The maximum absolute value is dictated by
the current location of the motor and the
range of the axis (see the LMV command
above).
LMV+HRUN <-1 | 0 | 1>
Starts and stops the horizontal
motor.
-1 = Moves the display left
0 = Stops the motor
1 = Moves the display right
LMV+VRUN <-1 | 0 | 1>
Starts and stops the vertical
motor.
-1 = Moves the display down
0 = Stops the motor
1 = Moves the display up
LMV+FRUN <-1 | 0 | 1>
Starts and stops the focus
motor.
-1 = Moves the display inward
0 = Stops the motor
1 = Moves the display outward
LMV+ZRUN <-1 | 0 | 1>
Starts and stops the zoom
motor.
-1 = Makes the display larger
0 = Stops the motor
1 = Makes the display smaller
Examples
Set the lens to H:1000, V:1500, Z:500, F:500:
(LMV 1000 1500 500 500)
Start to move horizontal motor toward positive max position:
(LMV+HRUN 1)
Stop the vertical motor:
(LMV+VRUN 0)
Start moving the zoom motor towards the negative max position:
(LMV+ZRUN -1)
Move the horizontal motor 45 steps in the positive direction:
(LMV+HSTP 45)
LOE–Video Loop Out Enable
Enables or disables video loop out on the THIC, 3GIC, and TDPIC cards.
Commands
Command
Description
Values
LOE <0 | 1>
Enables or disables video loop out. This
command is only available if video
electronics are on and it only applies to
0 = Disables video loop out
1 = Enables video loop out (Default)
Serial API commands
Boxer 4K Serial API Commands Technical Reference
35
020-101697-05 Rev. 1 (07-2017)
Copyright
©
2017 Christie Digital Systems USA Inc. All rights reserved.