Command
Description
Values
CCA+BOFW <blue of
white saturation
value>
CCA+RDPX <x
coordinate for red>
CCA+RDPY <y
coordinate for red>
CCA+GNPX <x
coordinate for
green>
CCA+GNPY <y
coordinate for
green>
CCA+BLPX <x
coordinate for blue>
CCA+BLPY <y
coordinate for blue>
CCA+WHPX <x
coordinate for
white>
CCA+WHPY <y
coordinate for
white>
Sets the native color primaries for the projector using
the x,y coordinate form, scaled by a factor of 10,000.
For example, an x value of 3350 corresponds to
x=0.3350 in the CIE 1931 chromaticity scale.
This command is only available if the video electronics
are on and Max Drives is selected. It is only available to
a service user.
The valid range for each value
depends on which of the Red,
Green, Blue, or White point is
being adjusted.
CCA+COPY <value>
Copies the values from one of the other pre-defined
color tables into the custom color table. This command
is only available if video electronics are on.
0 = Max Drives
1 = Color Temperature
2 = HD Video (ITU-RBT.709)
CCA+SAVE
Saves the current primary settings (for example, CCA
+RDPX, and so on) as the new default color primary
settings.
Save these settings after calibrating the color primaries
(such as measuring the primary x,y coordinates using a
spectroradiometer or similar equipment).
This command is only available if video electronics are
on. It is only available to a service user.
—
CCA+RSET
Resets the native color primary settings to their
defaults.
If primary settings have not been saved (CCA+SAVE),
this resets the primary settings to hard-coded defaults.
This command is only available if video electronics are
on. It is only available to a service user.
—
Examples
Use a custom color table:
(CCA+SLCT 3)
Serial API commands
Boxer 4K Serial API Commands Technical Reference
19
020-101697-05 Rev. 1 (07-2017)