(EVT!"--END--")
Retrieve all events from a specific point in time until now:
(EVT "2013-03-17 04:01:13")
Result:
(EVT!000 "2013-03-17 04:47:18.340" "OK" "Setting Time to 06:47:17")
(EVT!001 "2013-03-17 04:01:13.860" "Error" "(SST+TEMP?003) Lamp Exhaust Temperature
(Temp 3) = Communication fault (shutdown)")
(EVT!002 "2013-03-17 04:01:13.855" "Error" "(SST+TEMP?002) Air Intake Temperature
(Temp 2) = Communication fault (shutdown)")
(EVT!003 "2013-03-17 04:01:13.824" "Error" "(SST+TEMP?000) Integrator Rod Temperature
(Temp 1) = Communication fault (shutdown)")
(EVT!"--END--")
Retrieve all events between two specific points in time:
(EVT "2013-03-17 04:01:08" "2013-03-17 04:01:12")
Result:
(EVT!004 "2013-03-17 04:01:12.663" "Error" "(SST+VERS?017) Lamp Power Supply Version
= Detection fault")
(EVT!"--END--")
FCS–Lens Focus Position Adjustment
Sets the lens focus to an absolute position.
This command is only enabled when the projector is on.
Commands
Command
Description
Values
FCS <position>
Adjusts the lens focus to the specified position.
The position is persistent across AC cycles.
position = A numerical value
subject to the range returned in
FCS?m
FCS?m
Returns the minimum/maximum range of the zoom axis
based on the last lens calibration performed. The
returned range is persistent across AC cycles.
—
Examples
Move lens focus to position 500:
(FCS 500)
Serial API commands
Boxer 4K Serial API Commands Technical Reference
26
020-101697-05 Rev. 1 (07-2017)
Copyright
©