
Chore-Tronics Feeder Control
Wiring Diagrams
MT1559A
10/6/99
80
80
1
2
3
ON
4
5
1
2
3
ON
4
5
1
2
3
ON
4
5
1
2
3
ON
4
5
ON
1
2
3
4
5
AD #1
AD #2
AD #3
AD #4
MT1559-14 3/99
DURING NON-ALARM CONDITIONS, THE C AND N.O.
CONTACTS OF THE ALARM RELAY ARE CLOSED.
DURING ALARM CONDITIONS, THE C AND N.C.
CONTACTS OF THE ALARM RELAY ARE CLOSED.
INPUT POWER BEING OFF IS AN ALARM CONDITION.
SEE NOTE 1
NOTES:
1.
24 VDC POWER SUPPLY
VOLTAGE INPUT RANGE:
100 - 240 VAC
50/60 HZ. SINGLE PHASE
0.6 AMP.
SUPPLY VOLTAGE
100 - 240 VAC
50/60 HZ. 0.6 AMP.
GND
SUPPLY
L1 L2
24 VDC
-
+
RED
PUSH DOWN TO
OPEN TERMINAL
BLOCK
GND.
+
+24 VOLT DC
GROUND
-24 VOLT DC
I/O ADDRESS
FOR I/O NET
-
SJB CONTROL
WIRING DIAGRAM
120 OHM RESISTOR
SHIELD
SIGN.
WHITE
BLACK
V
V
GREEN
SIGN.
GND.
-
+
GND.
SJB CONTROL
- I/O +
FNET
NET
120 OHM RESISTOR
REQUIRED AT THE
BEGINING AND END
OF THE I/O NET
TO PC HOOK UP
(MUST HAVE C CENTRAL)
120 OHM
RESISTOR
- TO I/O NET
+ TO I/O NET
TWISTED PAIR
-
+
F NET
I/O NET
-
+
120 OHM
RESISTOR
- I/O +
NET
FNET
24V EXT GND
D 1
METER
WATER
WIRING DIAGRAM
FEED CONTROL
+24 VOLT SUPPLY TO
SJB (MAX 6 CELLS)
120 OHM RESISTOR
REQUIRED AT THE
BEGINING AND END
OF THE I/O NET
120 OHM RESISTOR
-24 VOLT SUPPLY TO
SJB (MAX 6 CELLS)
IF INTERNAL POWER
SUPPLY FAILS.
EX24 VOLT
SUPPLY FOR MANUAL
SWITCHES CAN BE
CONNECTED HERE
I/O BOARD WIRING
DRY CONTACTS
INPUT FROM
WATER METER
#1
#1
#8
#2
#4
#3
#2
#3
#4
#6
#5
#7
#5
#6
#7
#8
#1
#3
#1
#2
#4
#2
#3
#4
#3
#1
#2
#6
#5
#4
230 VAC 50/60 HZ.
L1 L2
INCOMING POWER
RELAY BOARD
1 HP MAX
WEIGH
BIN #1
FEEDER
FILL #1
LIGHT
FEEDER
#1
FEEDER
#2
WEIGH
BIN #2
FEEDER
FILL #2
WATER
CLOCK
230 VAC
SUPPLY
FEEDER
FILL #1
WEIGH
BIN #1
FEEDER
#1
LIGHT
FEED
BACK
LID
SWITCH
LID
SWITCH
FEED
BACK
230 VAC 50/60 HZ
SUPPLY
T3
T2
L3
L2
T1
L1
RELAY
ALARM
NO
C
NC
TYPICAL CONTACTOR
CONNECTION
230 VAC
SUPPLY
CONNECT THE REMAINING
LOAD CELL IN THE SAME
MANER.(MAX OF 6 LOADCELLS)
T3
L3
T2
T1
L2
L1
T1
L1
T3
L3
T1
T2
L1
L2
T3
L3
T1
T2
L2
L1
T3
L3
T2
L2
MALE FEEDER
W/HOPPER SCALE
LOAD CELLS
UNDER WEIGH BIN ONLY
EXAMPLE 6
MOTOR FOR
#1 FEEDER
FILL
230 VAC
SUPPLY
M
230 VAC
SUPPLY
MOTOR FOR
#1 FEEDER
M
M
LOAD TO
LIGHTS
M
230 VAC
SUPPLY
MOTOR FOR
#1 WEIGH-BIN
FILL AND
SCREENER
M
M
M
CONTACTOR
NOT SUPPLIED
CONTACTOR
NOT SUPPLIED
CONTACTOR
NOT SUPPLIED
CONTACTOR
NOT SUPPLIED
T1
L1
L3
T2
L2
CONTACTOR
NOT SUPPLIED
POWER SUPPLY
FOR WATER
SOLENOIDS
TO WATER
SOLENOID
MOTOR FOR
MALE FEEDER
M
T3
Wiring Diagram #6
3/25/99
Содержание Feeder Control
Страница 1: ...70 MT1559 01 7 98 MT1559A March 1999...