Chore-Tronics Feeder Control
Installation and Operation of Scale Load Cells
47
MT1559A
10/6/99
1. Mount Base - The Mount Base is the
heavy, steel frame that the bin leg sets on.
The Load Cell is secured within the Mount
Base. (T.C. type shown)
2. Load Cell - The Load Cells are the
sensing devices of the scale. They mount
inside the Base and are secured in place by
(2) pins. (T.C. type shown)
3. Top Mount - The Top Mount is the flat
steel plate that connects the bin leg to the
Mount Base.
Beam Assembly - The Beam Assembly is
used on 6-legged bins that are not to be
mounted on a bin platform. The (2) Beam
Assemblies carry the load of (2) legs each,
thus requiring (4) Mount Kits instead of 6.
The Beam Assemblies may be used on bins
that carry a maximum gross weight of
48,000 lbs (21,773 kg.)
Steel Framing - Steel framing is used in
applications that require both feed bins be
combined. One scale system is installed
beneath the steel framing.
(Frame not supplied by Chore-Time)
System Planning
Carefully plan the system layout prior to beginning the installation.
The bin should be installed so that no components (such as ladders, conveyors,
conduit, etc.) come in contact with the ground or other building structures in a way
that would cause an inaccurate weight reading.
The diagrams, on the following two pages show the common system layouts. Refer
to the diagram that best fits your particular application.
For bins with six legs, use of Beam Assemblies is recommended to
a Maximum of 24 tons (21772.8 kg).
Installation and Operation of Scale Load Cells
3
1
MF973-14 2/96
2
MF973-13 1/93
MF973-75 3/96
{Note}
*
3/25/99