Operation and Description of Function Settings
Chore-Tronics Feeder Control
40
MT1559A
10/6/99
Scale Junction Box Add-On’s
SJB - SJB1 (Scale Junction Boxes)
When using a scale system along with your feeder control, you will need a scale
junction box (SJB or SJB1) to attach the cables from the load cells, and to transmit a
signal to the control. Each SJB comes with a mounting bracket that allows you to
mount the box easily to a Chore-Time or Brock Bin.
When mounting the SJB or SJB1 to the bin, always make sure you
use water tight connectors and bring your cables through the
bottom of the box.
In addition to the cable inputs from the load cells, there will be a cable running to the
feeder control. There is no length restriction on the cable and we recommend using
our sensor cable part no. 42208 for this application.
There are two different junction boxes. The one you use depends on the weighing
application:
SJB (Scale Junction Box) #40733
This is recommended when your load cells are located under a separate bin from the
supply bin.
SJB1 (Scale Junction Box with Interrupt Switch) #41519
If you are weighing and feeding from the same bin (supply bin), then the SJB1 should
be used. The SJB1 has an interrupt switch which will temporarily stop the feeder fill
system in the event feed is being delivered during the feeding period. This will allow
you to maintain an accurate preset calculation.
When the delivery process is completed, the button is pushed again to resume the
feeder auger operation. If the button is not pushed a second time, the feeder auger will
automatically be activated 60 minutes after it was first deactivated.
See following pages for wiring diagram.