Chore-Tronics Feeder Control
Wiring Diagrams
MT1559A
10/6/99
77
77
WIRING DIAGRAM
SJB1 CONTROL
PUSH DOWN TO
OPEN TERMINAL
BLOCK
-24 VOLT DC
GROUND
+24 VOLT DC
SUPPLY VOLTAGE
100 - 240 VAC
50/60 HZ. 0.6 AMP.
L1
SUPPLY
-
24 VDC
GND
L2
+
+
24 VDC POWER SUPPLY
VOLTAGE INPUT RANGE:
100 - 240 VAC
50/60 HZ. SINGLE PHASE
0.6 AMP.
V
RED
BLACK
V
GREEN
SIGN.
WHITE
SIGN.
GND.
SHIELD
GND.
-
I/O ADDRESS
FOR I/O NET
120 OHM RESISTOR
SJB1 CONTROL
230 VAC 50/60 HZ.
INCOMING POWER
L1 L2
#4
#1
#3
#2
#6
#5
D 1
WATER
METER
24V EXT GND
FEED CONTROL
WIRING DIAGRAM
120 OHM
RESISTOR
TO PC HOOK UP
(MUST HAVE C CENTRAL)
DRY CONTACTS
- TO I/O NET
+ TO I/O NET
#1
BIN LID
SWITCH
TWISTED PAIR
120 OHM
RESISTOR
F NET
I/O NET
-
+
120 OHM RESISTOR
REQUIRED AT THE
BEGINING AND END
OF THE I/O NET
120 OHM RESISTOR
LID
SWITCH
LID
SWITCH
120 OHM RESISTOR
REQUIRED AT THE
BEGINING AND END
OF THE I/O NET
FEED
BACK
FEED
BACK
DRY CONTACTS
DRY CONTACTS
I/O BOARD WIRING
FNET
RELAY
C
NC
NO
ALARM
FNET
NET
- I/O +
- I/O +
NET
#2
#1
LEVEL SWITCH
RETURN
LEVEL SWITCH
RETURN
230 VAC 50/60 HZ
SUPPLY
-24 VOLT SUPPLY
+24 VOLT SUPPLY
DRY CONTACTS
INPUT FROM
WATER METER
L3
T3
L2
L1
T1
T2
#1
#3
#2
#1
#3
#2
#4
#4
FEEDER
FILL #1
CONTACTOR
CONTACTOR
NOT SUPPLIED
WEIGH
BIN #1
230 VAC
SUPPLY
230 VAC
SUPPLY
M M
FEEDER
#1
LIGHT
MOTOR FOR
#2 FEEDER FILL
#1
#1
#4
#3
#2
#3
#2
#4
#5
#7
#5
#6
#6
#8
#8
#7
RELAY BOARD
1 HP MAX
LIGHT
FEEDER
FILL #1
WEIGH
BIN #1
FEEDER
#1
WEIGH
BIN #2
FEEDER
#2
FEEDER
FILL #2
WATER
CLOCK
CONTACTOR
NOT SUPPLIED
CONTACTOR
T3
T2
T1
T3
T2
L3
L2
T1
L1
L3
L2
CONNECT THE REMAINING
LOAD CELL IN THE SAME
MANER.(MAX OF 6 LOADCELLS)
MOTOR FOR
#1 FEEDER
FILL
230 VAC
SUPPLY
TYPICAL CONTACTOR
CONNECTION
M
230 VAC
SUPPLY
M
L1
TO 24 VOLT FOR LIGHT.
TO #1 BIN LID SWITCH.
EXAMPLE 3
LIGHT
PUSH
BUTTON
NOT SUPPLIED
CONTACTOR
NOT SUPPLIED
LOAD CELLS
UNDER SUPPLY BIN
V
LOAD TO
LIGHTS
M
MOTOR FOR
#1 FEEDER
M
230 VAC
SUPPLY
M M
T1
T3
T2
T3
T2
T1
L1
L3
L2
L2
L1
L3
L3
L2
L1
T3
T2
T1
NOT SUPPLIED
MOTOR FOR
#2 FEEDER
TO WATER
SOLENOID
POWER SUPPLY
FOR WATER
SOLENOIDS
M M M M
MT1559-11 3/99
DURING NON-ALARM CONDITIONS, THE C AND N.O.
CONTACTS OF THE ALARM RELAY ARE CLOSED.
DURING ALARM CONDITIONS, THE C AND N.C.
CONTACTS OF THE ALARM RELAY ARE CLOSED.
INPUT POWER BEING OFF IS AN ALARM CONDITION.
SEE NOTE 1
NOTES:
1.
1
2
3
ON
4
5
1
2
3
ON
4
5
1
2
3
ON
4
5
1
2
3
ON
4
5
ON
1
2
3
4
5
AD #1
AD #2
AD #3
AD #4
Wiring Diagram #3
3/25/99
Содержание Feeder Control
Страница 1: ...70 MT1559 01 7 98 MT1559A March 1999...