Chapter 5 Function Parameter Detail SVF-MN Series Frequency Inverter Operation Manual
123
P110 Retain
P111 UP/DOWN terminal freq. 0.00
~
P03
0.00
This parameter is used to set the initial value of UP/DOWN
frequency.
P112 Start mode when restart after power cut
0
~
1 0
P113 Normal start mode selection
This parameter is used to select motor start mode.
0: Start from 0 Hz
1: Rotate speed track start
P114 Cooling fan start selection
0
~
1 0
0: Fan revolve when the drive run, fan stop when the drive stop
1: Always run
P115 PID goal source settings
0
~
4 0
0: Without PID function
1: Keyboard potentiometer settings
2: AVI
(
0
~
10V
)
settings
3: ACI
(
4
~
20mA
)
settings
4: PID setting address
(
refer to P125
)
PID control is a common method of process control, which
conduct ratio, integral, differential operation through dispersion of
the feedback signal of the controlled variable and target signal. To
consist of loop system and keep the controlled variable in target