SVF-MN Series Frequency Inverter Operation Manual Chapter 5 Function Parameter Detail
114
Setting sample: set stage speed 7 forward, stage speed 6 reverse,
stage speed 5 reverse, stage speed 4 forward, stage speed 3 forward,
stage speed 2 reverse, stage speed 1 forward, the meaning
corresponding to each bit is as follows:
Parameter number:
=bit7×2
6
+bit6×2
5
+bit5×2
4
+bit4×2
3
+bit3×2
2
+bit2×2
1
+bit1×2
0
=0×2
6
+1×2
5
+1×2
4
+0×2
3
+0×2
2
+1×2
1
+0×2
0
=0+32+16+0+0+2+0
=50
So parameter P79=50
☞