10-1
10. OPERATIONS
10.1. Fixed-Time Printing Intervals
Fixed-time printing is started after turning on the power supply. The following table shows an outline of
the intervals according to the printing contents.
Time and time line
Channel number
Chart speed
Scale, tag, engineering unit
Depends upon chart
speed
In the order of channel
number at about 6mm
intervals
About 84mm
intervals
In the order of channel
number at about 42mm
intervals
1. Printing intervals of time and time lines
Printing is interlocked with the chart speed and carried out at the following intervals. The start point of
intervals is 00: 00 hours.
Chart speed
Time, time line (Note)
Time line only
Year, month, day
1 to 9
12:00 hours only
6 hours
10 to 15
4 hours
2 hours
16 to 30
2 hours
1 hour
31 to 60
1 hour
61 to 119
1 hour
30 minutes
120 or over
30 minutes
00:00 hours only
(Note) Time lines only are printed if this printing overlaps with periodic data printing.
2. Printing intervals
of Channel numbers
○
1
Fixed-time printing is executed besides trace printing
(See note) with the same colors as trace printing in the
order of channel numbers at intervals of about 6mm.
(Note) Left side when printing is impossible on the right
side.
○
2
About 12mm intervals between channels 6 and 1.
3. Printing intervals of Chart speed
Chart speed is printed in black on the left side of the chart
once every 2 intervals (about 84mm) of channel numbers.
4. Scale, tag, and engineering unit
○
1
These data are printed in the order of channel numbers
on the right and left sides of the chart every interval
(about 42mm) of channel numbers.
○
2
Printing of these data is interlocked with channel
numbers, and the scale, tag, and unit of the channel are
printed.
○
3
Tag is not printed, if it is not programmed.
1
2
3 4 5 6
1
2
3 5 6
1 interval
≒
6mm × 7
≒
42mm
(No skip)
<Channel 4 is skipped>
Channel numbers printing
1
1 :TIC10
°C
1200
0
Scale
(lower-limit value)
Channel No.
Scale
(Higher-limit value)
Trace printing
Engineering
unit
Tag (Print if it is programmed)
Channel
Scale, tag, engineering unit