19.0 TROUBLE-SHOOTING AND EMERGENCY REMEDIES
N.B. OPERATIONS MARKED
◼
◼
MUST BE CARRIED OUT BY PROFESSIONALLY SKILLED PERSONNEL
AUTHORISED BY THE MANUFACTURER
ALL WORK MUST BE CARRIED OUT BY PROFESSIONALLY SKILLED PERSONNEL. BEFORE CARRYNG OUT ANY
MAINTENANCE JOBS IT IS MANDATORY TO STOP THE MACHINE AND DISCONNECT IT FROM THE POWER
SUPPLY.
19.1 TROUBLE-SHOOTING AND EMERGENCY REMEDIES FOR SCREW COMPRESSOR
FAULT FOUND
POSSIBLE CAUSES
OBSERVATIONS
1)
The machine does not start
1A
- no power
1B
- the transformer protection fuse is
interrupted
- check the power supply line,
Chapter 12.2
- replace fuse with new one of same
size.
2)
The machine does not start
The red LED (Ref. 5 Fig. 17/A) is
flashes.
The following pictograph appears
intermittently:
2A
- Phases incorrect
2B
- the main motor protection device
has tripped
2C
– Temperature switch on element
outlet has tripped
- Verify phase sequence
- to check possible motor failure
- environment temperature too high;
improve ventilation in the
compressor room, Chapter 9.2
◼
◼
- cooling radiator is dirty, clean the
radiator
- oil level too low; top up the oil tank
3)
The machine does not start
The red LED (Ref. 5 Fig. 17/A) is
flashes.
The following pictograph appears
intermittently:
3A
- The oil high temperature
protection has tripped
- environment temperature too high;
improve ventilation in the
compressor room, Chapter 9.2
◼
◼
- cooling radiator is dirty, clean the
radiator
- oil level too low; top up the oil tank
4)
The compressor does not reach
working pressure
4A
- the compressed air consumption
is too high
4B
- the discharge electrovalve
remains open, Ref. EV/SC wiring
diagram
◼
◼
- check the electric system
5)
Excess oil consumption
5A
- deteriorated oil separating filter or
oil level is too high
◼
◼
- change the oil separating filter,
Chapter 23