ENGLISH
28 Code 9828093379 ed 00 05/2020
OVERVIEW OF THE SCREENS
Menu item
Submenu
Digital input screen
Designation
<dAtA> Data
<d.1>
Calling up running hours
<d.2>
Calling up motor starts
<d.3>
Calling up module hours
<d.4>
Calling up loading hours
<d.5>
Calling up load solenoid valve
(only for 5.5-7.5kW units)
<d.6>
Calling up service timer
<ProG> Programming <rEG.P>
Regulation Pressure
<Pr.SL>
Calling up modifying pressure band selection
<LPr.1>
Calling up modifying pressure band settings
<uPr.1>
Calling up modifying pressure band settings
<LPr.2>
Calling up modifying pressure band settings
<uPr.2>
Calling up modifying pressure band settings
<tiMr> Timer
<SrV.d>
Calling up maintenance warning
<diSP>
Display
<tEMP>
Calling up modifying unit of temperature
<PrES>
Calling up modifying unit of pressure
<bC.LG>
Calling up modifying time of backlight
<Ctrl> Control
<Lo.rE>
Local/remote start/stop
<Ar.Af>
Calling up automatic restart after voltage failure
<Ar.d>
Delay automatic restart after voltage failure
<nHCA>
Number of hourly compressor activation
(only for 5.5-7.5 kW / 7.5-10 HP units and 4
kW / 5,5 HP single phase unit)
<PASS>
Activating password protection
<tEst> Test
<tSt. 1>
Display testing
<info> Info
<P.rEL>
Parameter Map Release
<F.rRl>
Firmware Release
<F.dAY>
Firmware Release Day
<F.Mnt>
Firmware Release Month
<F.YAr>
Firmware Release Year
<SEr.n>
Serial number