14.4.17
CALLING UP/MODIFYING PRESSURE BAND SETTINGS
Starting from the Main screen:
-
Press Enter button (7) for 3 seconds to enter the Main menu.
-
Select <ProG> and press Enter button (7) to enter the Programming menu.
-
Scroll Up or Down buttons (4-8) to <reG.P> for regulation pressure.
-
Press Enter button (7) to enter the submenu.
<LPr. 1> is parameter of Load Pressure band 1 <uPr. 1> is parameter of Unload Pressure band 1 <LPr.2> is parameter of Load Pressure band 2
<uPr.2> is parameter of Unload Pressure band 2
-
Scroll Up or Down buttons (4-8) and press Enter button (7) to select parameter.
-
The actually used pressure is shown. Scroll Up or Down buttons (4-8) to set pressure value and press Enter button (7) to confirm. The
unit blinks and the new setting is saved.
14.4.18
CALLING UP/MODIFYING THE UNIT OF TEMPERATURE
The unit of temperature measurement can only be changed when the compressor is stopped. Starting from the Main screen:
-
Press Enter button (7) for 3 seconds to enter the Main menu.
-
Select <ProG> and press Enter button (7) to enter the Programming menu.
-
Scroll Up or Down buttons (4-8) to <diSp> for display settings.
-
Press Enter button (7) to enter the submenu.
-
Scroll Up or Down buttons (4-8) to <tEMP> and press Enter button (7).
-
The act
ually used unit is shown. Possible settings are <˚C > and <˚F >.
-
Scroll Up or Down buttons (4-8) to set the unit of temperature and press Enter button (7) to confirm. The unit blinks and is saved.
14.4.19
CALLING UP/MODIFYING THE UNIT OF PRESSURE
The unit of pressure measurement can only be changed when the compressor is stopped. Starting from the Main screen:
-
Press Enter button (7) for 3 seconds to enter the Main menu.
-
Select <ProG> and press Enter button (7) to enter the Programming menu.
-
Scroll Up or Down buttons (4-8) to <diSp> for display settings.
-
Press Enter button (7) to enter the submenu.
-
Scroll Up or Down buttons (4-8) to <PrES> and press Enter button (7).
-
The actually used unit is shown. Possible settings are <bar>, <psi> and <MPa>.
-
Scroll Up or Down buttons (4-8) to set the unit of pressure and press Enter button (7) to confirm. The unit blinks and is saved.
14.4.20
CALLING UP/MODIFYING BACKLIGHT TIME
The backlight will be activated after pressing any button and for the interval of time set in the parameter <bC.LG> (in sec).
Starting from the Main screen:
-
Press Enter button (7) for 3 seconds to enter the Main menu.
-
Select <ProG> and press Enter button (7) to enter the Programming menu.
-
Scroll Up or Down buttons (4-8) to <diSp> for display settings.
-
Press Enter button (7) to enter the submenu.
-
Scroll Up or Down buttons (4-8) to <bC.LG> and press Enter button (7).
-
The current backlight setting is shown. It is possible to set a value between 0s and 1 20s.
-
Scroll Up or Down buttons (4-8) to set the time of backlight and press Enter button (7) to confirm. The unit blinks and is saved.