A shutdown warning will appear in the event of:
-
A too high temperature at the outlet of the compressor element.
Compressor element outlet temperature
-
If the outlet temperature of the compressor element exceeds the sh
utdown warning level (factory set at 110˚C/ 230˚F), warning LED
(5) is on.
-
Press Scroll up or down buttons (4-8). The screen shows the temperature at the compressor element outlet.
It remains possible to check the actual status of other parameters by pressing the enter button (7) for 3 seconds. Press button (3) to stop the
compressor and wait until the compressor has stopped. The warning message will disappear as soon as the warning condition disappears.
14.4.7 SHUTDOWN
DESCRIPTION
THE COMPRESSOR WILL SHUTDOWN:
-
In case the temperature at the outlet of the compressor element exceeds the shutdown level (detected by temperature sensor TT11) or
by temperature switch (TSHH11/TSHH21).
-
In case the pressure at the outlet of compressor exceeds the shutdown level (PT20)
-
In case of error of the outlet pressure sensor (PT20) or temperature sensor (TT11).
-
In case of overload of the compressor motor (M1)