ENGLISH
Code 9828093379 ed 00 05/2020 31
14.4.15
CALLING UP/RESETTING THE SERVICE TIMER
Starting from the Main screen:
-
Press Enter button (7) for 3 seconds to enter the Main menu.
-
Select <dAtA> and press Enter button (7) to enter the Data menu.
-
Scroll Up or Down buttons (4-8) until <d.6> and <hrs> is shown.
Press Enter button (7): the loading time is shown.
This screen shows the unit used <hrs> (or <x1 000 hrs>) and the value <1191>.
In the example shown, the compressor has run 1191 hours since the previous service.
To reset the timer, contact your supplier.
14.4.16
CALLING UP/MODIFYING PRESSURE BAND SELECTION
Starting from the Main screen:
-
Press Enter button (7) for 3 seconds to enter the Main menu.
-
Select <ProG> and press Enter button (7) to enter the Programming menu.
-
Scroll Up or Down buttons (4-8) to <reG.P> for regulation pressure.
-
Press Enter button (7) to enter the submenu.
-
Scroll Up or Down buttons (4-8) until <PrSL> is shown and then press Enter button (7).
-
Pressure band 1 (<SEL. 1>) is shown. Scroll Up or Down buttons (4
–
8) to pressure band 2 (<SEL.2>).
-
Press Enter button (7) on the desired pressure band.