background image

Page 6

SKU 97906

For technical questions, please call 1-800-444-3353.

of battery without a proper regulating 

device.

Have the equipment serviced by a 

7. 

qualified repair person using only 

identical replacement parts.  This will 

ensure that the safety of the equip-

ment is maintained.  Do not attempt 

any service or maintenance proce-

dures not explained in this manual 

or any procedures that you are un-

certain about your ability to perform 

safely or correctly.
Store equipment out of the reach of 

8. 

children.
Follow scheduled engine and equip-

9. 

ment maintenance.
Refueling Precautions:

10. 

Do not smoke, or allow sparks, 

a. 

flames, or other sources of ignition 

around the equipment, especially 

when refuelling.

Do not refill the fuel tank while the 

b. 

engine is running or hot.

Do not fill fuel tank to the top.  Leave 

c. 

a little room for the fuel to expand as 

needed.
Refuel in a well-ventilated area only.

d. 

generator precautionS

Set up

Do not connect generator directly 

1. 

into a home’s electrical lines.  Do 

not plug a generator into an outlet in 

the home.  Connecting a generator 

directly to a utility power supply can 

‘back feed’ along the power lines and 

kill or injure utility workers working on 

the lines.

All connections from the Generator to 

2. 

a load must be installed by a licensed 

electrician in compliance with all lo-

cal, state, and federal electrical codes 

and standards.
The generator must be grounded in 

3. 

accordance with all relevant electrical 

codes and standards before opera-

tion.
Insulate all connections and discon-

4. 

nected wires.
Connect the generator only to a load 

5. 

or electrical system (120 volt or 240 

volt) that is compatible with the elec-

trical characteristics and rated capac-

ities of the generator.
Set up the generator outdoors in a 

6. 

well-ventilated, dry area, away from 

building air intakes. The genera-

tor should be protected from direct 

exposure to rain and snow.  Do not 

set up the generator on a conductive 

surface such as a metal deck.
This generator is not intended to 

7. 

power sensitive electronic equipment 

without the addition of an appropriate 

line conditioner
Before connecting generator’s wiring:

8. 

Turn the engine switch to its “OFF” 

a. 

position.
Allow the engine to completely cool.

b. 

Then, remove the spark plug Wire(s) 

c. 

from the spark plug(s).

operation

Do not attempt to connect or discon-

1. 

nect load connections while standing 

in water or on wet ground.

Содержание 97906

Страница 1: ...uing improvements actual product may differ slightly from the product described herein Distributed exclusively by Harbor Freight Tools 3491 Mission Oaks Blvd Camarillo CA 93011 Visit our website at http www harborfreight com Read this material before using this product Failure to do so can result in serious injury Save this manual Copyright 2008 by Harbor Freight Tools All rights reserved No porti...

Страница 2: ...d Type Batteries 12 Technical Specifications 13 Mounting hole pattern 13 Shaft size type 13 Servicing 13 Maintenance Procedures 14 Engine Oil Change 14 Air Filter Element Maintenance 14 Spark Plug Maintenance 14 Fuel Filter Replacement if equipped 15 Cleaning Maintenance and Lubrication Schedule 15 After Initial 20 Operation Hour Period 16 Every 25 Operation Hours Thereafter 16 Every 50 Operation ...

Страница 3: ...ich if not avoided could result in minor or moderate injury NOTICE is used to address practices not related to personal injury CAUTION without the safety alert symbol is used to address practices not related to personal injury WARNING Read all instructions Failure to follow all instructions listed below may result in fire serious injury and or DEATH The warnings and precautions discussed in this m...

Страница 4: ...art pacemaker could cause pacemaker interference or pacemaker failure Caution is neces sary when near the engine s magneto or recoil starter Use only accessories that are recom 6 mended by Harbor Freight Tools for your model Accessories that may be suitable for one piece of equipment may become hazardous when used on another piece of equipment Do not operate in explosive atmo 7 spheres such as in ...

Страница 5: ...nt s operation If damaged have the equipment serviced before using Many ac cidents are caused by poorly main tained equipment Use the correct equipment for the 20 application Do not modify the equip ment and do not use the equipment for a purpose for which it is not in tended Service precautions Before service maintenance or 1 cleaning Turn the engine switch to its a OFF position Allow the engine ...

Страница 6: ...y power supply can back feed along the power lines and kill or injure utility workers working on the lines All connections from the Generator to 2 a load must be installed by a licensed electrician in compliance with all lo cal state and federal electrical codes and standards The generator must be grounded in 3 accordance with all relevant electrical codes and standards before opera tion Insulate ...

Страница 7: ...conductive object Use only Class BC or Class ABC fire 3 extinguishers on electrical fires Do not overload the generator Over 4 loading can cause fires in the electri cal cords in addition to generator and appliance damage Service Keep all electrical equipment clean 1 and dry Replace any wiring where the insulation is damaged Replace terminals that are worn or corroded Keep terminals clean and tigh...

Страница 8: ... damage to the engine and any other devices used with this product Unpacking When unpacking check to make sure that the item is intact and undamaged If any parts are missing or broken please call Harbor Freight Tools at the number shown on the cover of this manual as soon as possible Set Up Instructions Read the entire Important Safety Information section at the beginning of this manual including ...

Страница 9: ...nt be ing powered to reduce the length of extension cords Grounding Connect a 6 AWG grounding wire 1 not included from the Grounding Point 55a on the Generator to a grounding rod not included that has been driven at least 24 inches into the ground The grounding rod must be a copper or brass rod which can adequately ground the Generator Only a trained and licensed electri cian should perform this p...

Страница 10: ...ck the oil level The oil level should be between the high and low marks on the dipstick If the oil level is below the low mark 3 add the appropriate type of oil until the oil level is between the high and the low marks Oil type 32 F or above SAE 10W30 Below 32 F SAE 5W30 Replace the Oil Dipstick 4 CAUTION Do not run the engine with too little or too much oil The engine will be permanently damaged ...

Страница 11: ...ver to its RUN position IMPORTANT Allow the engine to run 7 at no load until warm 1 5 minutes with no load after each start up to al low the engine to stabilize Break in Period Breaking in the engine will help to 1 ensure proper equipment and engine operation and will extend the en gine s lifespan The warranty is void if the engine is not broken in properly The first 20 hours of operation is the b...

Страница 12: ...n handling Installing an inline regulator is recom 5 mended before charging Lead acid batteries are hazardous 6 Follow all instructions safety precau tions and charging procedures in cluded with the battery Start the Generator with no loads 7 attached Connect the clamps on the Battery Charging Cord 1a to the battery to be charged first red clamp to positive terminal and black clamp to negative ter...

Страница 13: ...ine Oil Type SAE 10W30 above 32 F SAE 5W30 at 32 F or below Capacity 0 42 Quarts Spark Plug Type E6TC DENSO W2OFP U Gap 0 6 0 7mm Valve Clearance Intake 0 15mm Exhaust 0 2mm Speed Maximum 3 600 RPM Mounting hole pattern mm mm M8 size thread hole 4 5 depth Shaft size type Servicing To prevent serious injury from accidental starting Turn the Power Switch of the equipment to its OFF position wait for...

Страница 14: ...e proper level follow 4 ing the instructions under the Starting the Engine section Air Filter Element Maintenance Wipe off the air cleaner cover 1 The air cleaner cover is held in place 2 by a wing nut or clamps Remove it Remove the air filter element 3 Cleaning 4 For paper filter elements To prevent injury from dust and debris wear ANSI approved safety goggles NIOSH approved dust mask respirator ...

Страница 15: ...d dust mask respirator and nitrile gloves Close fuel valve leading from gas 3 tank completely Take note of the fuel filter s orienta 4 tion Place a suitable container under the 5 fuel filter Disconnect the fuel lines leading to 6 and from the fuel filter and allow fuel to drain onto the container Install new fuel filter in the same 7 orientation Make sure to properly secure both fuel lines Clean u...

Страница 16: ...ith a fuel stabilizer intended for long term engine stor age not included After filling run engine for about 5 10 minutes to cir culate the treated gasoline through the carburetor Wait for engine to cool before proceeding Clean out area around spark plug c Remove spark plug and pour one tablespoon of engine oil into cylinder through spark plug hole Reinstall spark plug but leave spark d plug wire ...

Страница 17: ... and set choke to start position Clean or replace fuel filter 8 Ignition spark Related Spark plug wire not connected 1 securely Spark plug electrode wet or dirty 2 Incorrect spark plug gap 3 Spark plug wire or spark plug 4 broken Incorrect spark timing or faulty 5 ignition system Ignition spark Related Connect spark plug wire properly 1 Clean spark plug 2 Correct spark plug gap 3 Replace spark plu...

Страница 18: ...asoline Test replace fuel tank cap 3 Properly adjust idle speed 4 Have qualified technician diagnose 5 and service engine Engine knocks Old or low quality gasoline 1 Engine overloaded 2 Incorrect spark timing deposit 3 buildup worn engine or other mechanical problems Fill fuel tank with fresh 89 octane 1 unleaded gasoline Do not exceed equipment s load 2 rating Have qualified technician diagnose 3...

Страница 19: ... 50a Panel 1 51a Bolt M6x25 4 52a Power Switch 1 53a AC Circuit Protector 1 54a AC Outlet 2 55a Grounding Point 1 57a Battery Charging Socket 1 59a DC Circuit Protector 1 60a Rubber Gasket 1 61a Bracket for Capacitor 1 PLEASE READ THE FOLLOWING CAREFULLY The manufacturer and or distributor has provided the parts list and assembly diagram in this manual as a reference tool only Neither the manufact...

Страница 20: ...Page 20 SKU 97906 For technical questions please call 1 800 444 3353 ASSEMBLY DIAGRAM REV 09b ...

Страница 21: ... Piston Ring Set 1 39 Piston 1 40 Piston Pin 1 41 Piston Pin Clip 18mm 2 42 Connecting Rod Assembly 1 43 Connecting Rod Assembly 1 44 Connecting Rod Assembly 2 45 Cylinder Head Gasket 1 46 Oil Seal 1 47 Flange Bolt M8x25 6 48 Dipstick 1 49 Crankcase Cover 1 50 Ball Bearing 6303 1 51 8x14 Dowel Pin 2 52 Case Cover Packing 1 53 Camshaft 1 Engine PARTS LIST Part Description Qty 54 Valve Lifter 2 55 C...

Страница 22: ...Page 22 SKU 97906 For technical questions please call 1 800 444 3353 Engine diagram ...

Страница 23: ...epaired products at our expense but if we determine there is no defect or that the defect resulted from causes not within the scope of our warran ty then you must bear the cost of returning the product This warranty gives you specific legal rights and you may also have other rights which vary from state to state 3491 Mission Oaks Blvd PO Box 6009 Camarillo CA 93011 800 444 3353 Emission Control Sy...

Страница 24: ...e filed in accordance with the provi sions of the HFT warranty policy explained in the box at the top of the previous page HFT shall not be liable for any loss of use of the engine for any alternative usage for any damage to goods loss of time or inconvenience Warranty coverage shall also be excluded for any part which fails malfunctions or is damaged due to failure to follow the maintenance and o...

Отзывы: