Page 12
SKU 97906
For technical questions, please call 1-800-444-3353.
ment into the 110/120 volt AC Outlets
(54a). The Generator has an AC Cir-
cuit Protector (53a) to protect the unit
in case of an overload. If an overload
occurs, the Breaker will switch to its
“OFF” position and cause the Gen
-
erator to shut down. Press the Circuit
Protector button (53a) to reset the
Generator.
When finished using the Generator,
3.
turn the Power Switch (52a) to its
“OFF” position. Turn the Fuel Valves
(9a) to their “OFF” positions. Discon
-
nect all electrical powered tools and
equipment from the Generator’s AC
Outlets.
To prevent accidents, turn off the
4.
engine and disconnect its spark plug
wire after use. Wait for the engine to
cool, clean external parts with clean
cloth, then store the equipment out
of children’s reach according to the
Storage instructions in this manual.
to charge 12 v Lead-acid type
Batteries:
Batteries contain
corrosive acid that
can cause severe injury;
always wear anSi-approved
safety goggles and work
gloves when handling.
Installing an inline regulator is recom-
5.
mended before charging.
Lead-acid batteries are hazardous.
6.
Follow all instructions, safety precau-
tions, and charging procedures in-
cluded with the battery.
Start the Generator with no loads
7.
attached. Connect the clamps on
the Battery Charging Cord (1a) to the
battery to be charged first; red clamp
to positive terminal (+), and black
clamp to negative terminal (-), then
plug the Battery Charging Cord into
the Battery Charging Socket (57a).
Do not leave a battery unattended
8.
while it is charging.
warning! to prevent seri-
ous injury to people or property
damage; do not charge a battery
higher than its maximum rated
charge. over-charging a battery
can cause it to explode; spraying
the area with corrosive acid.
The Generator has a DC Circuit Pro-
9.
tector (59a) to protect the unit in case
of an overload. If an overload occurs,
the Breaker will switch to its “OFF”
position and cause the Generator
to shut down. Press the DC Circuit
Protector button (59a) to reset the
Generator.
After the battery has been charged,
10.
disconnect the plug from the charg-
ing outlet first, then disconnect the
clamps from the battery. Turn the
Power Switch and the Fuel Valves to
the “OFF” positions.