SKU 66523
For technical questions, please call 1-800-444-3353.
Page 15
Every 100 Operation Hours:
Replace Spark Plug.
a.
Replace Air Filter Element.
b.
Note:
All maintenance procedures sched-
uled for 25, 50, and 100 operation
hours should be performed at least
yearly.
Every 300 Operation Hours:
Clean Fuel Tank and Carburetor as-
a.
sembly.
Clean carbon build-up from Com-
b.
bustion Chamber.
Storage
Wait for Engine to cool, then wipe
1.
Engine with clean cloth.
When the equipment is to remain idle
2.
for longer than 20 days, prepare the
Engine for storage as follows:
Change engine oil and empty Fuel
a.
Tank.
Clean out area around Spark Plug.
b.
Remove Spark Plug and pour one
tablespoon of engine oil into Cylin-
der through Spark Plug hole.
Reinstall Spark Plug, but leave the
c.
Spark Plug Wire disconnected.
Pull Starter Handle to distribute oil
d.
in Cylinder. Stop after one or two
revolutions when you feel the Piston
start the compression stroke (when
you start to feel resistance).
Apply a thin coat of rust preventive oil
3.
to all uncoated metal parts.
Cover and store in a dry, well-ventilat-
4.
ed area out of reach of children.
Maintenance and Cleaning
Schedule: Generator
Before Every use:
Check to make sure all bolts and
a.
nuts are tight.
Check for any damage to the Gen-
b.
erator. If damaged, do not use
until repaired by a qualified service
technician.
After Every use:
Allow the unit to completely cool.
a.
Then clean the exterior of the Gen-
erator with a clean cloth.