Grasp the Starter Handle and pull
4.
slowly until resistance is felt. While
holding the Handle, allow the Starter
Rope to rewind slowly. Then, pull the
Starter Handle with a rapid, full arm
stroke. Once again while holding
the Handle, allow the Rope to rewind
slowly. Repeat as necessary, until
the Engine starts.
(See Figure E.)
FIGuRE E
STARTER HANdLE
After the Engine starts and warms up,
5.
slowly move the Choke Lever to its
“RUN” position.
(See Figure C.)
IMPORTANT: Allow the Engine to
6.
run at no load until warm (approx. 3
minutes) after each start-up to allow
the Engine to stabilize.
Break-in Period:
Breaking-in the Engine will help to
1.
ensure proper equipment and Engine
operation, and will extend the En-
gine’s lifespan. The warranty is void
if the Engine is not broken in properly.
The first 25 hours of operation is the
break-in period.
During this time frame, DO NOT
•
exceed 75% of the Generator’s load
limit. In other words, the maximum
load during this break-in period
should be no more than 700 watts.
After the first 25 hours of use:
•
Change the engine oil.
•
Under normal operating conditions
subsequent maintenance follows the
schedule explained in the MAINTE-
NANCE AND SERVICING section.
Equipment Operation
Load And Circuit Breakers:
The total combined load through any
1.
combination of outlets on the Genera-
tor must not exceed the rated power
(1300 watts peak; or 1,000 watts
rated) of the unit.
Always reduce the load if the AC
2.
Circuit Breaker or DC Circuit Breaker
trips off. Once the load is reduced,