16.

Do not touch the welding wire if you are in contact with the workpiece,
ground, or another welding wire from a different machine.

17.

Do not allow the welding wire to touch earth ground.  

Accidental earth

discharges may cause overheating and fire hazards.

18.

Do not pass equipment cables through or near lifting chains, crane cables,
or any electrical lines.

19.

Never use the Welder near water.  

Ensure that the surrounding area and cutting

objects are dry.  Do not spray water or other liquids on or near the Welder.

20.

Avoid all direct contact between the skin and wet garments and metal parts
under electrical power.  

Check that gloves and protective clothing are dry.

21.

Never leave the Welder unattended when it is plugged into an electrical
outlet.  

 Make sure to unplug it from its electrical outlet before leaving the area.

22.

Do not unplug the Welder by pulling on the Power Cord.  Keep the Power
Cord away from heated surfaces.

23.

Always turn off the Welder in the event of a power failure.

24.

Significant DC electrical voltage exists after turning off and unplugging the
Welder.  

Discharge the electrode to ground before handling.

25.

Performance of this Welder may vary depending on variations in local line
voltage.  

Extension cord usage may also affect tool performance.

26.

Always turn off the Welder and unplug the unit from its electrical outlet
before performing any inspection, maintenance, or cleaning procedures.

27.

Use the right tool or attachment for the right job.  

Do not attempt to force a

small tool or attachment to do the work of a larger industrial tool or attachment.
There are certain applications for which this product was designed.  It will do the
job better and more safely at the rate for which it was intended.  Do not modify
this product, and do not use this product for a purpose for which it was not
intended.

28.

         

WARNING!   

The brass components of this product contain lead, a

chemical known to the State of California to cause birth defects (or other
reproductive harm).  

(California Health & Safety code 25249.5, et seq.)

Содержание 55594

Страница 1: ...yright 2005 by Harbor Freight Tools All rights reserved No portion of this manual or any artwork contained herein may be reproduced in any shape or form without the express written consent of Harbor F...

Страница 2: ...npacking check to make sure all the parts shown on the Parts List on page 20 are included If any parts are missing or broken please call Harbor Freight Tools at the number shown on the cover of this m...

Страница 3: ...t fit contact a qualified electrician to install a polarized outlet Do not change the plug in any way Double insulation eliminates the need for the three wire grounded power cord and grounded power su...

Страница 4: ...Always wear eye protection Dusk mask non skid safety shoes hard hat or hearing protection must be used for appropriate conditions TOOL USE AND CARE 16 Use clamps not included or other practical ways t...

Страница 5: ...ection Maintenance And Cleaning section of this manual Use of unauthorized parts or failure to follow maintenance instructions may create a risk of electric shock burns or other injury SPECIFIC SAFETY...

Страница 6: ...r have the electronic equipment shut down temporarily 10 Prevent accidental fires Remove any combustible material from the work area When possible move the work to a location well away from combustibl...

Страница 7: ...ding make a thorough examination for evidence of fire Be aware that easily visible smoke or flame may not be present for some time after the fire has started Do not weld in atmospheres containing dang...

Страница 8: ...Keep the Power Cord away from heated surfaces 23 Always turn off the Welder in the event of a power failure 24 Significant DC electrical voltage exists after turning off and unplugging the Welder Disc...

Страница 9: ...ee prong grounding Plug The Plug must be connected to a properly grounded Outlet If the tool should electrically malfunction or break down grounding provides a low resistance path to carry electricity...

Страница 10: ...ollowing illustration See Figure A FIGURE A THREE PRONG PLUG 120 VOLT GROUNDED ELECTRICAL OUTLET THIS PRODUCT USES A THREE PRONG PLUG DOUBLE INSULATED TOOLS TOOLS WITH TWO PRONG PLUGS 1 Tools marked D...

Страница 11: ...d See Figure C 5 If you are using one extension cord for more than one tool add the nameplate amperes and use the sum to determine the required minimum cord size See Figure C 6 If you are using an ext...

Страница 12: ...Volts Alternating Current Amperes No Load Revolutions per Minute RPM FIGURE D NOTE For additional information regarding the parts listed in the following pages refer to the Assembly Diagram on page 21...

Страница 13: ...Ground Clamp Make sure the Handle Grip covers the area where the Ground Cable is attached to the Ground Clamp See Figure F 6 NOTE The Welder produces powerful electrical currents It is critical that y...

Страница 14: ...rode Cable to the Electrode Handle by tightening the Screw onto the end of the Electrode Cable See Figure G 5 With the Electrode Cable secured to the Electrode Holder 27 slide the Handle Grip over the...

Страница 15: ...e Shield 26 See Figure H FACE SHIELD 26 FACE SHIELD HANDLE LENS LENS HOLDER BRACKET FIGURE H OPERATING INSTRUCTIONS Welding Equipment Duty Cycle And Overheating 1 IMPORTANT Welding longer than the rat...

Страница 16: ...yed action type circuit breaker or fuses See Figure I amperage or voltage or duty cycle before welding 4 This Welder at its 10 at 55 AMPs duty cycle low can run continuously under load for 1 minute ou...

Страница 17: ...tilt the Electrode forward at an angle of approximately 30 degrees and hold it at a distance from the workpiece equal to the diameter of the Electrode See Figure I 9 NOTE The Thermal Protection Indic...

Страница 18: ...llows A The speed at which you advance along the weld B The length of arc C The rate of amperes at which you are welding Adjusting one or more of these three factors can help increase the quality of w...

Страница 19: ...r AC welding Electrode 8 Use a rod of 0 078 diameter maximum INSPECTION MAINTENANCE AND CLEANING 1 WARNING Make sure the Power Switch 9A is in its OFF position Unplug the Power Cord Plug from its elec...

Страница 20: ...ND OR DISTRIBUTOR EXPRESSLY STATES THAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD BE UNDERTAKEN BY CERTIFIED AND LICENSED TECHNICIANS AND NOT BY THE BUYER THE BUYER ASSUMES ALL RISK AND LIABILITY ARIS...

Страница 21: ...AM NOTE Some parts are listed and shown for illustration purposes only and are not available individually as replacement parts 1 2 3 4 5 6 7 8 9A 10 11 12 13 9B 14 15 16 17 18 19 20 21 22 22 23 22 24...

Страница 22: ...SKU 55594 For technical questions please call 1 800 444 3353 Page 22 ELECTRICAL SCHEMATIC...

Отзывы: