background image

SKU 55594

For technical questions, please call 1-800-444-3353.

Page 9

29.

        

 WARNING!  

This product, when used for welding, cutting, and similar

applications, produces chemicals known to the State of California to cause
cancer and birth defects (or other reproductive harm).
(California Health & Safety code 25249.5, et seq.)

Improperly connecting the grounding wire can result in the risk of electric

shock.  Check with a qualified electrician if you are in doubt as to whether the

outlet is properly grounded.  Do not modify the power cord plug provided with

the tool.  Never remove the grounding prong from the plug.  Do not use the

tool if the power cord or plug is damaged.  If damaged,  have it repaired by

a service facility before use.  If the plug will not fit the outlet, have a proper

outlet installed by a qualified electrician.

GROUNDED TOOLS: TOOLS WITH THREE  PRONG  PLUGS

1.

Tools marked with “Grounding Required” have a three wire Cord and three prong
grounding Plug.  The Plug must be connected to a properly grounded Outlet.  If
the tool should electrically malfunction or break down, grounding provides a low
resistance path to carry electricity away from the user, reducing the risk of electric
shock.  

(See Figure A, next page.)

2.

The grounding prong in the Plug is connected to the green wire inside the Cord to
the grounding system in the welding equipment.  The green wire in the Cord

GROUNDING

WARNING!

30.

         WARNING!  

People with pacemakers should consult with their physician(s)

before using this product.  Operation of electrical equipment in close proximity to
a heart pacemaker could cause interference or failure of the pacemaker.

31.

        WARNING!  

Welding and cutting fumes and gases may be hazardous if

inhaled for long periods of time.

32.

        

WARNING!  

The warnings, precautions, and instructions discussed in this

instruction manual cannot cover all possible conditions and situations that may
occur.  It must be understood by the operator that common sense and caution
are factors which cannot be built into this product, but must be supplied by the
operator.

SAVE THESE  INSTRUCTIONS

Содержание 55594

Страница 1: ...yright 2005 by Harbor Freight Tools All rights reserved No portion of this manual or any artwork contained herein may be reproduced in any shape or form without the express written consent of Harbor F...

Страница 2: ...npacking check to make sure all the parts shown on the Parts List on page 20 are included If any parts are missing or broken please call Harbor Freight Tools at the number shown on the cover of this m...

Страница 3: ...t fit contact a qualified electrician to install a polarized outlet Do not change the plug in any way Double insulation eliminates the need for the three wire grounded power cord and grounded power su...

Страница 4: ...Always wear eye protection Dusk mask non skid safety shoes hard hat or hearing protection must be used for appropriate conditions TOOL USE AND CARE 16 Use clamps not included or other practical ways t...

Страница 5: ...ection Maintenance And Cleaning section of this manual Use of unauthorized parts or failure to follow maintenance instructions may create a risk of electric shock burns or other injury SPECIFIC SAFETY...

Страница 6: ...r have the electronic equipment shut down temporarily 10 Prevent accidental fires Remove any combustible material from the work area When possible move the work to a location well away from combustibl...

Страница 7: ...ding make a thorough examination for evidence of fire Be aware that easily visible smoke or flame may not be present for some time after the fire has started Do not weld in atmospheres containing dang...

Страница 8: ...Keep the Power Cord away from heated surfaces 23 Always turn off the Welder in the event of a power failure 24 Significant DC electrical voltage exists after turning off and unplugging the Welder Disc...

Страница 9: ...ee prong grounding Plug The Plug must be connected to a properly grounded Outlet If the tool should electrically malfunction or break down grounding provides a low resistance path to carry electricity...

Страница 10: ...ollowing illustration See Figure A FIGURE A THREE PRONG PLUG 120 VOLT GROUNDED ELECTRICAL OUTLET THIS PRODUCT USES A THREE PRONG PLUG DOUBLE INSULATED TOOLS TOOLS WITH TWO PRONG PLUGS 1 Tools marked D...

Страница 11: ...d See Figure C 5 If you are using one extension cord for more than one tool add the nameplate amperes and use the sum to determine the required minimum cord size See Figure C 6 If you are using an ext...

Страница 12: ...Volts Alternating Current Amperes No Load Revolutions per Minute RPM FIGURE D NOTE For additional information regarding the parts listed in the following pages refer to the Assembly Diagram on page 21...

Страница 13: ...Ground Clamp Make sure the Handle Grip covers the area where the Ground Cable is attached to the Ground Clamp See Figure F 6 NOTE The Welder produces powerful electrical currents It is critical that y...

Страница 14: ...rode Cable to the Electrode Handle by tightening the Screw onto the end of the Electrode Cable See Figure G 5 With the Electrode Cable secured to the Electrode Holder 27 slide the Handle Grip over the...

Страница 15: ...e Shield 26 See Figure H FACE SHIELD 26 FACE SHIELD HANDLE LENS LENS HOLDER BRACKET FIGURE H OPERATING INSTRUCTIONS Welding Equipment Duty Cycle And Overheating 1 IMPORTANT Welding longer than the rat...

Страница 16: ...yed action type circuit breaker or fuses See Figure I amperage or voltage or duty cycle before welding 4 This Welder at its 10 at 55 AMPs duty cycle low can run continuously under load for 1 minute ou...

Страница 17: ...tilt the Electrode forward at an angle of approximately 30 degrees and hold it at a distance from the workpiece equal to the diameter of the Electrode See Figure I 9 NOTE The Thermal Protection Indic...

Страница 18: ...llows A The speed at which you advance along the weld B The length of arc C The rate of amperes at which you are welding Adjusting one or more of these three factors can help increase the quality of w...

Страница 19: ...r AC welding Electrode 8 Use a rod of 0 078 diameter maximum INSPECTION MAINTENANCE AND CLEANING 1 WARNING Make sure the Power Switch 9A is in its OFF position Unplug the Power Cord Plug from its elec...

Страница 20: ...ND OR DISTRIBUTOR EXPRESSLY STATES THAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD BE UNDERTAKEN BY CERTIFIED AND LICENSED TECHNICIANS AND NOT BY THE BUYER THE BUYER ASSUMES ALL RISK AND LIABILITY ARIS...

Страница 21: ...AM NOTE Some parts are listed and shown for illustration purposes only and are not available individually as replacement parts 1 2 3 4 5 6 7 8 9A 10 11 12 13 9B 14 15 16 17 18 19 20 21 22 22 23 22 24...

Страница 22: ...SKU 55594 For technical questions please call 1 800 444 3353 Page 22 ELECTRICAL SCHEMATIC...

Отзывы: