1.
Securely clamp the Ground Clamp (28) to the metal object that is to be welded.
(See Figure I.)
2.
Set the Current Switch
MIN/MAX
(9B) to the desired setting (
MIN
= A
low setting
of 55 AMPs,
MAX
= a
high setting of 70 AMPs).
NOTE:
Use the
MIN
setting for
thinner metals and the
MAX
setting for
thicker metals.
(See Figure I.)
3.
Make sure the Power Switch
ON/OFF
(9A) is in the
“OFF”
setting. Then, plug
the Power Cord Plug of the Welder into the nearest 120 volt, 30 AMP, grounded,
electrical outlet with delayed action type circuit breaker or fuses.
(See Figure I.)
amperage or voltage, or duty cycle, before welding.
4.
This Welder, at its
10% at 55 AMPs
duty cycle (low), can run continuously under
load for
1
minute
out of each
10
minute
period. After using continuously for one
minute, the Welder must sit unused for 9 minutes. At its
6% at 70 AMPs
duty
cycle (high), the Welder can run continuously under load for
36 seconds
out of
each
10 minute period
. After using continuously for 36 seconds, the Welder
must rest for approximately 9-1/2 minutes.
To Operate The Welder:
THERMAL PROTECTION INDICATOR LIGHT (8)
ELECTRODE CABLE
GROUND CABLE
GROUND CLAMP (28)
AC ELECTRODE
(NOT INCLUDED)
METAL WORKPIECE
ELECTRODE
HOLDER
(27)
CURRENT SWITCH (MIN/MAX)
(9B)
POWER SWITCH (ON/OFF) (9A)
FIGURE I