background image

 
 

Instructions for installation and use. Reproduction prohibited. 07/ 2010 version 2.0 TAM 

30 

8) Contractual Guarantee 

 

8.1 – Duration 
 

The  guarantee  period  is  2  years,  for  all  parts  manufactured  by 
ourselves  with  the  exception  of  wear  parts,  as  from  the  date  of 
delivery by the installer or the sales outlet. 
It  applies  throughout  this  period  to  all  material  or  manufacturing 
defects.  We  shall  only  undertake  to  replace,  free  of  charge,  parts 
recognised as defective after verification by ourselves. 
 

8.2 – Legal guarantee 
 

The  provisions  of  the  guarantee  are  not  excluded  from  the 
purchaser’s use of the equipment covered by the legal guarantee for 
hidden  faults and  defects, which  applies  in  all  circumstances  under 
the conditions of Articles 1641 and following of French Civil Law. 
 

8.3 – Validity 
 

The  purchaser  designated  overleaf  acknowledges  having  received 
installation  instructions  and  agrees  to  comply  with  them.  The 
guarantee  is  only  valid  if  the  appliance  is  used  in  compliance  with 
recommendations  set  out  in  the  instructions  supplied  with  the 
appliance. 

 

8.4 – Exclusion 
 

8.4.1 Wear parts 

The door and window joints, hearth and decorated back, the baffle and the 
refractory  elements  are  wear  parts  and  are  therefore  guaranteed  for  one 
year as from the date of delivery of the appliance. 
 

 
8.4.2 Window 
 

Vitroceramic windows are excluded from the guarantee. 
 

8.4.3 General points 
 

Travelling  expenses,  transport,  labour,  packaging  and  dismantling  costs, 
as  well  as  the  consequences  of  non-use of  the  appliance,  resulting  from 
operations under the guarantee, shall be borne by the customer. 
 
Any malfunction of the appliance brought about by mechanical or electrical 
components not supplied by us and which are prohibited in the documents 
regarding the heating appliances, is excluded from the guarantee. 
 
Damage caused by use of any fuel other than wood. 
 
The  guarantee  does  not  apply  in  the  following  cases,  (this  is  not  an 
exhaustive  list):  but  not  in  these  alone:  installation  and  assembly  of 
appliances  for  which  Cheminées  de  Chazelles  is  not  responsible. 
Consequently,  Cheminées  de  Chazelles  cannot  be  held  responsible  for 
material damage or accidents to individuals following from installation not 
complying with legal and regulatory provisions, such as normal wear and 
tear of the equipment or its abnormal use, in particular in cases of use of 
the equipment in conditions different from those for which it was designed; 
it  is  formally  prohibited  to  modify,  transform  or  attempt  to  service  the 
appliance.  
 

 

Содержание e1000

Страница 1: ...tion and above all for use of the appliance Chemin es de Chazelles reserves the right to modify installation and use instructions for installation and use at any time Diagrams and images are not contr...

Страница 2: ...Instructions for installation and use Reproduction prohibited 07 2010 version 2 0 TAM 2 E 1000 E 900 E 1200 RANGE OF E INSERTS...

Страница 3: ...3 5 2 2 Installation 3 5 3 Natural or forced convection 3 5 3 1 NATURAL CONVECTION 3 6 Installing the jambs and corbels 3 7 Insulation of the surround 3 7 1 Incombustible surrounds 3 7 2 Combustible...

Страница 4: ...lace s surround comply with regulations in force and or are compatible with the manufacturer s recommendations the combustion air supply duct required for the appliance s proper operation exists and i...

Страница 5: ...building less than eight metres distant 2 1 5 2 Stack outlet on terrace In the case of a terrace roof or roof with a slope less than 15 the discharge end must be located at least 1 2 metres from the...

Страница 6: ...n the case of bricked flues see table in paragraph 2 2 2 For the safety distance to be complied with in the case of metal flues see table in paragraph 2 2 3 2 2 Safety distance 2 2 1 General points Th...

Страница 7: ...stible surrounds Surrounds must be protected using material with a minimum thermal resistance of 0 7 m2 K W at 50 C or of 0 4 m2 K W at 200 C classed as A1 or at least M0 or A2 s1 d0 equivalent to 30...

Страница 8: ...regular cleaning Grille mesh should be greater than 3 mm 2 4 4 Air inlet flow If the combustion air supply crosses through an outside wall with a lining the crossing must be airtight 2 4 5 Discharge...

Страница 9: ...inlet with an aluminium shaft 3 5 Installation of a Chazelles Design insert 3 5 1 General points Set up of the insert must comply with national regulatory directives 3 5 2 Specific instructions for in...

Страница 10: ...e window located inside the fairing To do so unscrew all the screws on the upper cover 3 5 2 2 2 Remove the upper cover 3 5 2 2 3 Remove the protective cardboard from the window 3 5 2 2 4 Replace the...

Страница 11: ...11 3 5 2 2 5 Using the handle or 2 cool hands lower the door window closing it completely 3 5 2 2 6 Rescrew the 2 side screws completely 3 5 2 2 7 Now attach the deflectors Start with the first roof s...

Страница 12: ...to model 3 5 2 2 9 Position the intermediate support inside the hood start by positioning the deflector furthest to the left and then position the others one by one 3 5 2 2 10 Now place the V bar whi...

Страница 13: ...chamber see maximum wood load in the characteristics of each insert Overloading the appliance with fuel when it is at normal draught is wasteful resulting in lower output and increased consumption Th...

Страница 14: ...pper fairing 3 5 3 1 3 Connect the rings 2 for the E900 E1000 and 4 for the E1200 to the mouths with at least 1 metre of aluminium tubing not supplied Note if you wish to install the ventilator at a l...

Страница 15: ...se of the insert work inside the combustion chamber as follows start by unscrewing the screws on the side uprights keeping the heat resistant components in place 3 5 3 2 5 Push the vermiculite side pa...

Страница 16: ...e Reproduction prohibited 07 2010 version 2 0 TAM 16 3 5 3 2 9 Unscrew the screws in the central bottom plate 3 5 3 2 10 Take out the bottom plate 3 5 3 2 11 Run the ventilator cables through the hole...

Страница 17: ...m of the flat gasket located on the bottom plate at the same level as the motor is connected 3 5 3 2 15 Unscrew the screw holding the plaquette on the bottom plate and push it to the right opening the...

Страница 18: ...9 Screw the sensor on the upper bottom plate 3 5 3 2 20 Reposition the upper bottom plate in its place 3 5 3 2 21 Rescrew the upper bottom plates 3 5 3 2 22 Repeat all the steps in reverse order to re...

Страница 19: ...utonomous mode and its range may be selected by the SPEED key in MANUAL mode the device emits a continuous sound signal Three different air ranges can be selected by pressing the SPEED 1 2 3 key to co...

Страница 20: ...must be ascertained that the insulation does not obstruct combustion and convection air supplies 3 7 2 Combustible surrounds See paragraph 2 3 3 2 4 Connecting duct 4 1 General points Connecting ducts...

Страница 21: ...using the connecting device specially designed by the manufacturer of the insulated flue The whole outside section of the first part of the flue must emerge in the room in which the fireplace is locat...

Страница 22: ...d must be visible to enable checking of the connecting duct or the insulating material that might surround it 5 2 2 Special precautions Before constructing the hood the following precautions must be t...

Страница 23: ...against using resinous woods pine fir spruce etc 6 3 Prohibited fuels All fuels other than wood are prohibited coal and its by products in particular Burning straw cardboard and liquid fuels is dange...

Страница 24: ...of wood slivers is well alight open the door load the appliance with the recommended fuel and work the controls until you obtain the desired power If you wish to increase draught you can increase air...

Страница 25: ...for example To obtain the output values indicated on the insert specifications during testing we used Output test loads Loads of 4 1 kg of beech wood Three 25cm long logs Air regulation systems Prima...

Страница 26: ...he handle or the cool hands supplied 6 7 Maintenance 6 7 1 Removing ashes The air required for combustion of wood arrives beneath the grille when the primary air damper is open and also keeps the gril...

Страница 27: ...cleaning of the appliance the connecting duct and the flue is recommended at the end of the season 6 7 6 Sweeping Mechanical sweeping of the flue is essential It should be carried out at least twice...

Страница 28: ...air damper to position 1 Leave the door closed Remove any easily inflammable materials from the neighbourhood of the appliance Call the fire brigade and leave the premises Keep a watch on events outsi...

Страница 29: ...ndow outside guarantee Open the door as indicated above for cleaning the window but without removing the special key Take hold of the door putting pressure on the upper right part while pushing to the...

Страница 30: ...affle and the refractory elements are wear parts and are therefore guaranteed for one year as from the date of delivery of the appliance 8 4 2 Window Vitroceramic windows are excluded from the guarant...

Страница 31: ...al documents on use and maintenance to ensure proper operation of the appliance PURCHASER Date Surname First name s Address Town Country Signature VENDOR document to be returned within the month follo...