Page 14
OLX V5.2 05.04
Max. Allowable Operating Temperature
95°C
Max. Allowable Operating Pressure
3 bar (Pressure Class 2)
Test Pressure
4.5 bar
Heat Output Range
11-13 kW
Heat Input at Rated Output
15 kW
Oil Pump Pressure
110 - 140 psi
Required Flue Draught
0.07 in H O (0.17 mbar)
Exit Flue Gas Temp
205°C
Exit Flue Gas Mass Flow
……kg/s
Exit Flue Connection Diameter
130 mm socket to take 125 mm (5 in) or
100 mm (4 in) pipe
Air Inlet Diameter
55 mm socket to take 50 mm (2 in) pipe
Max. Recommended Air Pipe Length
10M + 4 x 90° Swept Bends
Water-side Resistance
Range of Temperature Control
40 - 90°C
Safety Thermostat Temperature
110°C
Fuel Type Used
Kerosene 28 second
Boiler Type
On / Off Type
Boiler Tapping size
1 in BSP Female
Electrical Protection
IP20
Earthing Terminal
Copper Flashed Steel
Electrical Supply
240v 50 Hz
Electrical Power Input @ 240v ac (standard)
200 Watts
(with fan heater)
2200 watts
Fuse in Flame Effect
250v 2A x 20 mm
Fuses Required in Power Supply
Flame Effect only
3A 240V
Flame Fan Heater
10A 240V
Burner
3A 240V
Fire Valve Operating Temperature
90°C
Boiler Water Volume
23.4 Litres
Total Weight of Stove
140 Kg
2
4.1 mbar @DT=10°C
@ flow rate 2.9 litres/min
1.5 mbar @DT=20°C
OLX Boiler - Specifications