GENERAL POINTS
CONTROLLING THE BOILER
Before using the boiler for the first time, check with the
installer that it has been correctly installed and
commissioned. Do not attempt to use the boiler before
it has been commissioned.
The boiler is set up to burn 28 sec. viscosity oil, this is
commonly known as Kerosene. Do not use Gas Oil.
The boiler is controlled by the thermostat which is on
the left hand side of the fire, it is the lower of the two
control knobs (see Fig. 1.) This sets the temperature
that the boiler will operate at. A Central Heating Time
Clock or Programmer will normally control the heating
system.
The electric flame effect operates completely
independently from the boiler and is switched on and
off by the top control knob on the left hand side of the
fire (see Fig. 1.) Turn the knob to position "1" to
operate the flame effect. The flame effect may take a
few moments to become established when first
switched on after long periods of not being used.
Position "2" is used for the 1KW setting of the optional
fan heater if fitted. Position “3” is the 2KW setting. If
the room temperature becomes excessive, the internal
thermostat will switch the heater to blow cool air until
the temperature falls, when it will revert to its previous
setting.
FUEL
ELECTRIC FLAME EFFECT & FAN HEATER
IF THE BURNER FAILS TO LIGHT
MAINTENANCE
If the burner fails to light then the Reset light on the
Burner Reset Button may light up (see Fig. 2.) This
situation is known as “Lockout” in which case wait for
1 minute and press the re-set button (located through
the hole in the front panel behind the doors.) The
burner will then try to ignite again.
If the burner continually goes to lockout, then the cause
needs to be established and the problem put right. The
most common causes are lack of fuel, or air in the fuel
line. Check that the oil tank is not empty, and that all
valves are open. The troubleshooting guide gives
further steps, some of which will require action by a
trained Oil Engineer. Do not press the reset button
more than five times in a row as this can cause damage
to the pump.
It is important to have the appliance serviced each
year. Please arrange this with an OFTEC approved
Heating engineer. The flexible oil supply hose must be
replaced every 2 years
Replacing the bulb in the flame effect is a simple
operation that can be carried out without using any
tools.
Ensure that the flame effect is switched off before
attempting to replace the bulb. Open the doors and
Replacing The Flame Effect Bulb
Page 4
OLX V5.2 05.04
Burner Reset Button
Located Through Hole
In Front Panel
Fig 2. Burner Reset Button
Serial number Label
Bottom plate
Inner plate
Содержание OLX
Страница 2: ......
Страница 7: ...Page 7 OLX V5 2 05 04 ...
Страница 16: ...Charnwood OLX Electrode Settings All dimensions are in mm 9 0 1 0 3 0 0 2 0 5 0 5 Page 16 OLX V5 2 05 04 ...
Страница 19: ......