25
(12)
Origin reset, home:
Reset the origin at front-left, then move to home;
(13)
Nozzle 1\2 to UpCamera:
Move nozzle 1\2 to position of up camera;
(14)
Home (back-right):
Move head to home at back-right.
Note: Parameters changed in this window will not be saved.
Figure
11.1.
Window after “Diagnostics”, showing diagnostic functions.
12.
Set
The set window is used to set parameters.
(1)
Vacuum checks:
Click to globally toggle on and off; described previously;
(2)
Vision centering:
Click to globally toggle on and off; described previously;
(3)
Visual component detection
: Click to toggle on and off. If checked, when a
component is not detected on nozzle, then new material will be re-picked. After 6
times not detecting a component, the machine alarms and stops;
(4)
Detect Z-Axis
: Check to start Z axis detect. If checked, the Z axis is found to be
lost when the stick is attached, then the Z axis is automatically returned to the
origin. This feature can be avoided due to the high level of the device is not set up
to cause the Z axis, damage to the device parts;
(5)
Place Speed:
Global set of running speed of machine;
(6)
System set:
Set advanced parameters with special codes;
(7)
Date and time set:
Setting system time;
(8)
Clear statistic logs:
Click to clear all statistic logs;