Circuit diagram for mains
connection and motor
230V / 1-phase
F1
Thermal fuse, control voltage
F2
Thermal overload protection for motor
K1
Protection OPEN
K2
Protection CLOSEM Motor (230 V / 50
Hz)
S3
Safety limit switch OPEN (normally
closed contact)
S4
Safety limit switch CLOSE (normally
closed contact)
S7
Safety switch, emergency manual
operation (normally closed contact)
T1
Transformer
X1
Terminal block for mains connection
X2
Terminal block for motor
X4
Terminal block for mains voltage
selection
Picture of general wiring 1-Phase 230Volt
motor
•
Connection to motor via motor
protection switch
•
Limit switch connected (right side)
•
Ground wire connected to board
Not shown:
Connect mains to:
L2
= L- 230Volt
L1
= N Neutral
PE =
PE
ATTENTION:
Terminal X4 must have a jumper
between terminals 1+2 installed!
(Picture 1)
Pic. 1