Model 

Number: 

  SLY2500 

SLY2500E2 

Controller 

   none 

 CB400 

 

 
Max. Gate weight 

(kg) 

 

2500kg  

2500kg  

Motor 

Protection 

Switch 

  yes 

 yes 

Hold to run function 

 

 

no 

 

yes 

Automatic 

function 

  no 

 yes 

IR-Sensor 

   no 

 yes 

Automatic close  

 

 

no 

 

yes* 

Flashing 

Light 

   no 

 yes* 

Safety 

edges 

 

   no 

 yes* 

Emergency 

Stop   no 

 yes* 

Radio 

    no 

 external 

External Light switching function 

no 

 

yes* 

Traffic light with Red-Light  

 

no 

 

yes* 

* requires optional ZM-SKS-B plug in card 

Technical Data 

Voltage 

 

    230V 

 

Phases 

    1 

Frequency 

   50Hz 

Capacitor 

   2 

16µF 

 

Current 

(nominal) 

  3,85A 

 

Power 

    0,55 

kW 

Torque 

(max.) 

   120Nm 

 

Gear 

Reduction 

   1:40 

Duty Cycle Rating  

 

 

50%  

Temperature 

Range 

  -25/+55°C 

Thermal 

Protection: 

  140°C 

IP-Rating 

 

   IP55 

 

Gate 

Speed 

   10m/min 

 

Sprocket    90mm 

Module 

Weight 

    41kg 

INSTALLATION OF DRIVE  

The base for the drive can either be concreted or, if 
appropriate, made of steel.  
The concrete plinth needs to be of an appropriate size 
(approx. 80cm long x 80cm wide x 100cm deep). 

 
Notice:  

Precisely determine the height of the plinth 

(motor mounting socket) and the distance from the gate 
prior to installation. You are advised to work as 
precisely as possible. 
 

MOUNTING MOTOR AND GEAR UNIT 

The weight of the gate should not be borne by the cog 
wheel! Position the drive via the adjustment holes such 
that its location vis-à-vis the rack bar complies with the 
installation dimensions. 

 
MOUNTING RACK BAR 

The easiest way to fit the rack bar is to first place it on 
the motor's drive cog, disengage the motor and, by 
pushing the gate further with the rack bar, screwing the 
bar bit by bit firmly in position. In this way, you ensure 
that the rail bar engages with the cog wheel in an 
optimum manner. While doing this, do not forget to 
mark each fixing point. 

Notice:

 

Steel racks are recommended (320001 = 1m) 

For gates with weights above 3.000kg it is recommended to 
use two steel racks.  
The tooth racks should be fitted as shown with an overlap 
from rack to rack. For two rack mounting the M8 screw must 
be replaced with a longer type to suit the application. 

 

Содержание LiftMaster Professional SLY2500

Страница 1: ...SLIDING GATE OPERATOR Installation SLY2500 For gates up to 2 500kg www liftmaster de Email info chamberlain de Chamberlain GmbH Alfred Nobel Strasse 4 D 66793 Saarwellingen Germany 11 2008 b ...

Страница 2: ...round deformation etc High outdoor temperatures can lead to premature initiation of temperature protection switch Notice Motors are not designed to run permanent run continuous operation Outside temperature and gate represent important parameters for actual operating duration Attention This product may only be installed from professional installers Only qualified and trained electricians may conne...

Страница 3: ...cm wide x 100cm deep Notice Precisely determine the height of the plinth motor mounting socket and the distance from the gate prior to installation You are advised to work as precisely as possible MOUNTING MOTOR AND GEAR UNIT The weight of the gate should not be borne by the cog wheel Position the drive via the adjustment holes such that its location vis à vis the rack bar complies with the instal...

Страница 4: ...d with screws immediately INITIAL OPERATION Check gate functionality manually when the drive has been disengaged Electrical operation is possible only if a controller CB400 is connected ELECTRICAL CONNECTION See electrical wiring diagram with control board CB400 Control board pre installed Limit switch pre wired to NC contacts Motor pre wired to control board box Control board box pre installed Al...

Страница 5: ...99 5 EG Declaration of Incorporation Automatic Gate Opener Models when installed and maintained according to all the Manufacturer s instructions in combination with a Gate which has also been installed and maintained according to all the Manufacturer s instructions meets the provisions of EU Directive 89 392 EEC and all amendments I the undersigned hereby declare that the equipment specified above...

Страница 6: ...CONTROL BOARD KIT CB400 for AC SLIDING GATE OPERATORS Installation Instructions www liftmaster de Email info chamberlain de Chamberlain GmbH Alfred Nobel Strasse 4 D 66793 Saarwellingen Germany ...

Страница 7: ... the relevant electrical regulations are trained in the use and care of appropriate safety equipment are capable of recognising the dangers associated with electricity Scope of these instructions These instructions describe the installation and options for the product CB400 control board AS210B Some features require the optional ZM SKS plug in logic board to work This manual should only be used to...

Страница 8: ...requires ZM SKS B plug in card IMPORTANT BEFORE the installation of control board make sure it is checked if your control motor requires to be set for 400Volt 3 Phase or 230Volt 1 Phase X4 terminal A Test button OPEN direction S01 A Test button CLOSE direction S02 X1 Terminals Mains X2 Terminals Motor safety circuit of drive X3 Terminals Command devices X4 Terminals Selection 230V 400V X5 Terminal...

Страница 9: ...ps 1 Remove cover of operator 2 Remove control board box cover 3 Compare general pre assembly of control board Picture 1 230Volt 1 Phase motor assembly Picture 2 400Volt 3 Phase motor with motor protection switch installed 4 Install the control board holders 4 pieces into the marked holes See picture 3 Pic 1 Pic 2 Pic 3 ...

Страница 10: ...ty switch emergency manual operation NC contact T1 Transformer X1 Terminal block for mains connection X2 Terminal block for motor X4 Terminal block for mains voltage selection 1 2 230Volt 2 3 400Volt Picture of general wiring 400Volt shows Connection to motor via motor protection switch Limit switch connected right side Ground wire connected to board Not shown Connect mains to L1 L L2 L L3 L PE PE...

Страница 11: ...Safety switch emergency manual operation normally closed contact T1 Transformer X1 Terminal block for mains connection X2 Terminal block for motor X4 Terminal block for mains voltage selection Picture of general wiring 1 Phase 230Volt motor Connection to motor via motor protection switch Limit switch connected right side Ground wire connected to board Not shown Connect mains to L2 L 230Volt L1 N N...

Страница 12: ... switch OPEN Terminal block X3 Safety Devices and Commands 14 15 STOP Input 12 13 OPEN Direction Input 10 11 CLOSE Direction Input 7 8 9 Safety Edges Closed Direction Requires the ZM SKS module 5 6 Output 24Volt DC max 150mA 5 6 3 4 Radio input Automatic operation Requires the ZM SKS module 1 2 Photocell Close connection Requires the ZM SKS module EXAMPLE OPEN STOP CLOSE 4 lead solution EXAMPLE OP...

Страница 13: ...ology Closing direction Terminal 5 24Volt Terminal 6 Ground Terminal 2 Signal Notice A 4 wire photocell requires a jumper to be added 5 For relay photocell with 4 wire technology OPENING direction Terminal 14 15 Signal Terminal 5 24VDC Terminal 6 24VDC MORE OPTIONS For Chamberlain 2 wire photocells the optional 600213 2 interface box is required Three more photocells or safety edges may be connect...

Страница 14: ...J3 must be inserted X7 Socket Socket for the ZM SKS plug in board If the terminal is not used by the module the jumper marked J5 must be inserted X10 Socket Terminal for press and release full open and full close Opening direction J1 Closing direction J2 J1 and J2 jumper OPEN if ZM SKS board is used J1 and J2 jumper CLOSED if not connected WARNING If jumper J2 is inserted the safety edge output do...

Страница 15: ...ts Potential free normally open contact min 10 mA max 230V AC 4A Contacts used once for power switching can not be subsequently used for connecting small currents Temperature range In operation 10 C 45 CIn storage 25 C 70 C Air humidity up to 80 not condensing g k 8 1 x o r p p a t h g i e W Guidelines Standards Declaration of Conformity Gate Control Board for SLY2500 and 3500 AS210B is in conform...

Отзывы: