GENERAL CONNECTIONS:
Terminals X5 and X2
Limit switches
1.
Limit switch OPEN
2.
Limit switch CLOSE
3.
xx??
4.
Pre-limit switch CLOSE (after activation the
door does not reverse)
5.
Thermal overload protection for motor
6.
Emergency operation (normally closed
contact)
7.
Safety limit switch CLOSE
8.
Safety limit switch OPEN
Terminal block X3
Safety Devices and Commands
14 + 15 STOP Input
12 + 13 OPEN Direction Input
10 + 11 CLOSE Direction Input
7, 8 + 9 Safety Edges Closed Direction.
Requires the ZM-SKS module
5 + 6 Output 24Volt DC , max . 150mA
5=
+
6=
--
3 + 4 Radio input (Automatic operation)
Requires the ZM-SKS module
1 + 2 Photocell Close connection
Requires the ZM-SKS module
EXAMPLE:
OPEN/ STOP CLOSE (4 lead solution)
EXAMPLE:
OPEN / CLOSE
Terminal block X9
1 + 2 Dry Contact for red light traffic light
or other lights
X5
X2
X3
X9