EXTERNAL SAFETY- DEVICES
Connection (wiring) examples:
Requires optional ZM-SKS-B module to be
installed
1.
For optoelectric safety edges:
Closing direction
Settings:
Dipswitch 1 = OFF
Terminal 9:
+12Volt
Terminal 8:
Signal
Terminal 7:
Ground
2.
For 8.2KOhm safety edges
Closing direction
Settings:
Dipswitch 1 = ON
Terminal 7+ 8
3.
For pneumatic safety edges
Closing direction
Settings:
Dipswitch 1 = ON
Dipswitch 2 = ON
8.2KOhm resistor in place
Terminal 7+8
4.
For relay photocell with 3-wire
technology
Closing direction
Terminal 5:
+24Volt
Terminal 6:
Ground
Terminal 2:
Signal
Notice: A 4-wire photocell requires a
jumper to be added
5.
For relay photocell with 4-wire
technology
OPENING direction
Terminal 14+15:
Signal
Terminal 5 :
+ 24VDC
Terminal 6 :
- 24VDC
MORE OPTIONS:
•
For Chamberlain 2-wire photocells the
optional 600213-2 interface box is
required. Three more photocells or safety
edges may be connected and monitored
independently, Type suitable 8.2KOhm
type or mixed with 2-wire Chamberlain
photocells. The interface box can be
connected to any terminal and connected
to the safety output protecting the opening
OR the closing direction. The box is IP55
and can be located outside.