3 SPECIAL FUNCTIONS
3.1
FLUE CLEANER
” FUNCTION
This function is used to perform proper boiler combustion analysis and maximum and minimum gas
calibration.
Follow the instructions below to enable it:
PRESS
DISPLAY
The display will show this indication
Press Reset button for 5 continuous seconds
With the boiler on “Winter” mode, the 3-way valves is positioned on “heating” and the burner turns on
even without heating requested.
With the boiler o
n “summer” mode:
o
without sanitary demand the burner turns on in heating;
o
with sanitary demand the burner turns on in sanitary.
The delivery temperature (NTC1) is checked during the “Flue cleaner” function, as follows:
“summer” mode → Off: 86°C; On: 81°C;
“winter” mode → Off: 89°C; On: 84°C.
Three different powers can be selected when the function is enabled
PRESS
DISPLAY
POWER
Turn the knob
anticlockwise
Maxi power in
heating mode
Max power in
sanitary mode
Turn the knob
anticlockwise
Minimum power