Page. 11 of 73
Training manual :PIGMA Gal Evo
1.4.2
Indications of operating modes displayed on the screen
During the working of the appliance, it’s possible to verify the status of the boiler
:
ECRAN
DESCRIPTION
ETAT CHAUDIERE
Stand-By
STAND-BY
. No request.
Adjustment of
heating request
Adjustment of the heating request by the button n° 4.the
number indicates the set point. They blink during 5 s
Heating mode,
burner ON and SRA
function
The radiator who symbolise the heating circuit is surrounded,
that fame is enable and there is an indication of the level
power
Heating mode,
burner OFF and
SRA function
End of the heating request, the boiler is OFF but there is a
post-circulation of 3 min (default value)
Adjustment of
sanitary request
Adjustment of the sanitary request by the button n° 8.the
number indicates the control temperature. They blink during
5 s
Sanitary tapping,
burner ON n
The tap who symbolise the sanitary circuit is surrounded,
that fame is enable and there is an indication of the level
power
Comfort mode,
burner ON
The boiler is operating an tank heating mode, the 2 numbers
indicate the control temperature for sanitary system
En puisage sanitaire
brûleur éteint.
End of the sanitary request, the boiler is OFF but there is a
post-circulation of 3 min (default value)
Anti-frost function
ON
The anti- frost function is activate, management with the
NTC1 delivery sensor.
Solar system
connected by E-Bus
Solar system is connected by E-Bus to the boiler
TEST mode
Combustion analysis
Purge mode
Air purge function
Содержание PIGMA Gal Evo
Страница 10: ...Page 10 of 73 Training manual PIGMA Gal Evo...
Страница 52: ...Pag 52 de 73 Manuale Didattico ACO Training manual PIGMA Gal Evo...
Страница 56: ...Pag 56 de 73 Manuale Didattico ACO Training manual PIGMA Gal Evo 6 1 1 Diagramme lectronique FF boiler...
Страница 57: ...Pag 57 de 73 Manuale Didattico ACO Training manual PIGMA Gal Evo...
Страница 58: ...Pag 58 de 73 Manuale Didattico ACO Training manual PIGMA Gal Evo 6 1 2 Diagramme lectronique CF boiler...