Pag. 61 de 73
Manuale Didattico – ACO
Training manual :PIGMA Gal Evo
7.2
COMPLETE MENU
7.2.1
Menu 0 : Network
7.2.2
MENU 2 : BOILER PARAMETERS
Menù
S
ub
Menù
P
a
ra
m
e
te
r
Function
Range
Default
setting
0
2
BUS NETWORK
0
2
0
Network presence in the bus
(only visualization)
/
0
4
USER INTERFACE
0
4
1
Backlight time (min)
1 ÷ 10 ; 24h
24h
0
4
2
Thermoregulation button
deactivation
0 - 1
0
Menu
S
ub
Menu
P
a
ra
m
e
te
r
Function
Range
Default
setting
2
0
GENERAL
2
0
0
DHW set point temperature
36 ÷ 60
/
2
2
GENERAL
2
2
0
Slow ignition as % of the
maximum heating power
0 ÷ 100
See gas
table
2
2
1
Modulation ratio 1/10
0: Off
1: On
1
2
2
3
Floor thermostat or Room
thermostat zone 2 selection
0: Floor thermostat
1: Room thermostat zone 2
0
2
2
4
Thermoregulation
0: disabled
1: enabled
0
2
2
5
Heating delay restart
0: disabled
1: 10 seconds
2: 90 seconds
3: 210 seconds
0
2
2
8
Boiler version
0: combi
1: Storage with NTC (tank)
2: only heating or storage with
thermostat
3: micro-storage
Depend on
the boiler
version
2
2
9
Boiler nominal power
0 ÷ 100 kW
Depend on
the boiler
2
3
CENTRAL HEATING-1
2
3
0
Maximum heating power
(heating absolute maximum
power percentage) (%)
0 ÷ 100
2
3
1
Maximum heating power
(heating absolute maximum
power percentage) (%)
0 ÷ 100
See gas
table
2
3
5
Select of heating delay manage
0: manual
(set with par. 2 36)
1: automatic
1
2
3
6
Heating delay (min), enabled by
par. 2 35= 0
0 ÷ 7
3
Содержание PIGMA Gal Evo
Страница 10: ...Page 10 of 73 Training manual PIGMA Gal Evo...
Страница 52: ...Pag 52 de 73 Manuale Didattico ACO Training manual PIGMA Gal Evo...
Страница 56: ...Pag 56 de 73 Manuale Didattico ACO Training manual PIGMA Gal Evo 6 1 1 Diagramme lectronique FF boiler...
Страница 57: ...Pag 57 de 73 Manuale Didattico ACO Training manual PIGMA Gal Evo...
Страница 58: ...Pag 58 de 73 Manuale Didattico ACO Training manual PIGMA Gal Evo 6 1 2 Diagramme lectronique CF boiler...