Page. 43 of 73
Training manual :PIGMA Gal Evo
5.3.5
Clocking for heating restart aftr burner flame out
Control measure acted by parameter
2 36
It is possible to set up a clocking between 0 and 7 min in the time interval between burner shut off and
the following re-ignition . This set up is accomplished by parameter
2 36
provided that parameter
2 35
is set to 0.
5.3.6
Control of maximum heating power
There are 2 different types of maximun power in heating mode :
1.
Absolute power in heating
can be adjusted by use of parameter
2 30
. This value allows
the operator to set a maximum « limit » to the gas valve, which differs from usual maximun
power. This limit must be verified and changed, if necessary, in the event gas quality or the
electronic PCB are changed.
G20
G25
G30
G31
PUISSANCE
UTILE kW
Pression
gaz
mbar
réglage
%
Pression
gaz
mbar
réglage
%
Pression
gaz
mbar
réglage
%
Pression
gaz
mbar
réglage
%
25 kW CF
11,37
62
***
***
26,5
84
34,0
91
25 kW FF
12,0
62
***
***
25,9
90
34,5
93
30 kW FF
12
63
***
***
25,98
85
35,3
92
35 kW FF
10,3
59
***
***
25,3
83
33
93
2
.
Heating system power
is
adjustabl
e
by use of partameter
2 31
.
This value shall be
adjusted
systematically at the time when the installator sets the system into operation.
This value is adjustable as from minimum power level up to conrolled power level in menu
2 30
.
PIGMA 24 CF
G20
G25
G30
G31
POWER kW
Pressure
gas
mbar
Setting
%
Pressure
gas
mbar
Setting
%
Pressure
gas
mbar
Setting
%
Pressure
gas
mbar
Setting
%
9,9
2,2
0,0
***
***
5,5
0,0
6,0
0,0
11,0
2,7
37,0
***
***
6,8
50,0
7,4
52,0
12,0
3,2
39,0
***
***
8,0
54,0
8,8
56,0
13,0
3,8
42,0
***
***
9,4
58,0
10,3
59,0
14,0
4,4
44,0
***
***
11,0
61,0
12,0
63,0
15,0
5,0
47,0
***
***
12,6
64,0
13,7
66,0
16,0
5,7
49,0
***
***
14,3
67,0
15,6
70,0
17,0
6,5
52,0
***
***
16,2
71,0
17,6
72,0
18,0
7,2
54,0
***
***
18,1
73,0
19,8
76,0
20,0
7,6
55,0
***
***
18,9
75,0
23,5
80,0
21,0
8,3
57,0
***
***
20,8
77,0
26,0
83,0
22,0
9,1
59,0
***
***
22,9
80,0
28,5
87,0
23,0
10,0
61,0
***
***
25,0
83,0
31,1
90,0
23,7
10,6
64,0
***
***
26,5
84,0
33,0
93,0
Содержание PIGMA Gal Evo
Страница 10: ...Page 10 of 73 Training manual PIGMA Gal Evo...
Страница 52: ...Pag 52 de 73 Manuale Didattico ACO Training manual PIGMA Gal Evo...