CG Drives & Automation, 01-5980-01r2
Functionality
69
8.1
Preferred View [100]
This menu is displayed at every power-up. During
operation, the menu [100] will automatically be displayed
when the keyboard is not operated for 5 minutes. The
automatic return function will be switched off when the
Toggle and STOP/RESET keys are pressed simultaneously
for 5 seconds. As default the electrical power and current
values are displayed (example in the figure below):
Fig. 49 Default initial display.
Menu [100], “Preferred View” displays the settings made in
menu [110], “1st Line”, and [120], “2nd Line”.
8.1.1
1st Line [
110
]
This menu sets the content of the upper row in the menu
[100] “Preferred View
.
If “Process Value” is selected, the
menu shows the value of the selected process source in menu
[321].”
8.1.2
2nd Line [120]
Sets the content of the lower row in the menu
[100] “Preferred View”. Same selection as in menu [110].
8.2
Main Setup [200]
The “Main Setup” menu contains the most important
settings to get the softstarter operational and set up for the
application. It includes different sub menus concerning the
control of the unit, motor data and protection, utilities and
automatic reset of faults. This menu will instantaneously
adapt to installed options and show the required settings.
8.2.1
Operation setup [210]
Selections concerning the used motor, softstarter mode,
control signals and serial communication are described in
this submenu and is used to set the softstarter up for the
application.
Language [211]
Select the language used in the control panel display. Once
the language is set, this selection will not be affected by the
“Load Default” command.
Select Motor [212]
This menu is used if you have more than one motor in your
application. Select the motor to define. It is possible to define
up to four different motors, M1 to M4, in the softstarter. For
parameter set handling including motor sets M1 - M4, see
section 8.2.5, page 80.
Read-only
Default:
El Power
Dependent on menu
Process Val
0
Process value
Torque
2
Torque
Shaft Power
4
Shaft power
El Power
5
Electrical power
Current
6
Current
Heatsink Tmp
10
Heatsink temperature
Motor Temp
11
Motor temperature
SoftstStatus
12
Softstarter status
Run Time
13
Run Time
Energy
14
Energy
Default:
Current
100
0kW
Stp 0.0A
100
(1st Line)
Stp
(2nd Line)
110 1st Line
Stp
El Power
120 2nd Line
Stp
Current
Default:
English
English
0
English selected
Svenska
1
Swedish selected
Nederlands 2
Dutch selected
Deutsch
3
German selected
Français
4
French selected
Español
5
Spanish selected
Ρусский
6
Russian selected
Italiano
7
Italian selected
Č
esky
8
Czech selected
Türkçe
9
Turkish selected
Default:
M1
M1
0
Motor Data [220] is connected to
selected motor.
M2
1
M3
2
M4
3
211 Language
Stp
English
212 Select Motor
Stp
M1
Содержание emotron TSA Series
Страница 1: ...Emotron TSA Softstarter Instruction manual English Valid from Software version 1 27...
Страница 2: ......
Страница 4: ......
Страница 6: ...2 CG Drives Automation 01 5980 01r2...
Страница 12: ...8 Introduction CG Drives Automation 01 5980 01r2...
Страница 18: ...14 Mounting CG Drives Automation 01 5980 01r2...
Страница 42: ...38 Application guidelines CG Drives Automation 01 5980 01r2...
Страница 46: ...42 Getting started CG Drives Automation 01 5980 01r2...
Страница 70: ...66 Main features CG Drives Automation 01 5980 01r2...
Страница 142: ...138 Functionality CG Drives Automation 01 5980 01r2...
Страница 158: ...154 Troubleshooting Diagnoses and Maintenance CG Drives Automation 01 5980 01r2...
Страница 160: ...156 Options CG Drives Automation 01 5980 01r2...
Страница 168: ...164 Technical data CG Drives Automation 01 5980 01r2...
Страница 202: ...CG Drives Automation 01 5980 01r2 198...
Страница 203: ......