Installation
Important notes
42
CG Drives & Automation
Stop!
Pluggable terminal strips or plug connections
Plugging or removing the terminal strips or plug connections during operation
may cause high voltages and arcing.
Possible consequences:
Damage of the devices
Protective measures:
Switch off device.
Only plug or remove the terminal strips or plug connections in deenergised
status.
Stop!
Damage of the device
Mounting or dismounting of the controller, especially the Drive Unit can
damage or destroy the device.
Possible consequences:
The drive may respond in an uncontrolled manner and cause further
damages.
Protective measures:
Only mount or dismount the controller in deenergised status.
Stop!
The device contains components that can be destroyed by electrostatic
discharge!
Before working on the device, the personnel must ensure that they are free of
electrostatic charge by using appropriate measures.
Stop!
No device protection if the mains voltage is too high
The mains input is not internally fused.
Possible consequences:
Destruction of the device if the mains voltage is too high.
Protective measures:
Observe the maximally permissible mains voltage.
Fuse the device correctly on the supply side against mains fluctuations and
voltage peaks.