Commissioning
CG Drives & Automation
61
Before switching on
6.3.1
Before switching on
The wiring unit is mounted and wired as described in the instructions,
–
directly on a motor clamping flange or
–
with the wall adapter on a suitable surface near the motor.
Connections with the mains, motor, etc. have been established.
The communication unit has been mounted and wired according to the scheduled
application.
–
Input and output signals
–
Fieldbus
(depending on the version, only optionally available)
If required, the basic settings for "local mode" have been carried out.
–
Potentiometer
The drive unit has been mounted and screwed together.
Use available control functions reasonably, e.g.
–
Inhibit controller enable
–
Set speed adjustment to the minimum setting
Danger!
Great hazard potential during commissioning
Incorrect settings may cause unexpected and dangerous motor and system
movements.
Possible consequences:
Damage to material assets
Injury to persons
Protective measures:
Clear hazardous area
Observe safety instructions and safety clearances